Instruction Manual ATB-80, ATB-100, ATB-120
Following recommendations with regard to the exchange intervals result from the experiences of our
customers with the employment of the ATB compressor with an ambient temperature between -10°C
and +40°C and a humidity below 80%.
Type/Series
Up to 150 mbar
maximum working
pressure*
ATB-80
ATB-100
36 months
ATB-120
*) The working pressure is made up as follows:
The maximum hydraulic head above the blower components
Pressure loss through blower components
(e.g. Tube-, plate or disc aerator – as rule 50-70 mbar)
Check valve in the valve housing (valve box)
Pressure loss through demagnetisation of the permanent magnets
Pressure loss through cross-section reductions in the air hose (internal diameter smaller than
13mm) also caused by kinks or load deformation.
Depending on operating conditions the listed components are subject to a normal operational wear
and should be checked in the course of maintenance and, with wear or malfunction should be
exchanged:
Diaphragm
Connection lines
Valves in the valve box
Filters
Seals (bottom tank)
Rubber damper
Air connection pieces
a) Loosen the four casing screws. If the cover is difficult to
open take a screwdriver and insert it carefully in the
opening of casing – with this, do not damage the
casing seal.
b) Remove damping mat and loosen motor cover screws
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com
Art.-Nr.: 9060 0306 / Version: 17.08.2020 / Page 28 de 48
Up to 200 mbar
maximum working
pressure*
24 months
Up to 250 mbar
maximum working
pressure*
18 months