Instruction Manual ATB-80, ATB-100, ATB-120
3.3.4. Hose connection
The connection hose at the air outlet, for the ATB series, must have an internal diameter of at
•
least 13mm and an external diameter of at least 19 mm.
Laying of the hose should be as short as possible and straight. The overall length should not
•
exceed 5m.
Should more than 5m be necessary please contact us.
Ensure that there are no foreign bodies and/or kinks in the pipe, which can enter/occur during
•
installation.
•
The pump should be connected to the pipe by means of an L-air
connection piece. The connection should be secured.
The actual maximum back pressure of 250 mbar
•
(ATB-80/-100/-120) must not be exceeded!
3.3.5 Operation
The mains cable should be neither damaged nor loaded under tension.
•
•
Do not touch mains cable with wet hands.
Before working in water please pull out the mains plug.
•
Do not use the mains cable to pull out the mains plug.
•
Do not clean the pump with water.
•
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com
Art.-Nr.: 9060 0306 / Version: 17.08.2020 / Page 26 de 48