SELF CALIBRATION
Proceed as following for machine self calibration.
-Mount any wheel on the shaft, even if not balanced; better still if of an average size.
-Preset the exact dimensions of the wheel mounted.
NOTE: Presetting of incorrect dimensions could mean the machine is not correctly calibrated and therefore all sub-
sequent measurement will be incorrect until a new self-calibration is performed with the correct dimensions;
Remove the master weight from the wheel and balance the wheel according to the previously described proce-
dures.
The value measured by the machine with this self-calibration cycle is automatically memorized in a special
memory which retains them even when machine is switched off. Hence when the machine is switched on again, it
is ready to operate correctly. However, self-calibration can be carried out whenever required or when there is
some doubt whether the machine is operating correctly.
Until the positioning LED's pass from
flashing to being steady
Add a weight of 100 grams on the
outside in any angular position
It is important not to knock the
wheel during this spin
Machine calibrated