Electrical Requirements - Bertazzoni KMC30X Instructions D'installation

Masquer les pouces Voir aussi pour KMC30X:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A
time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in
accordance with the electrical rating of this unit as specified on the serial/rating plate located inside
the unit near the field wiring compartment.
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other materials, DO
NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or
grounding circuit could result in electrical shock.
• Check with a qualified electrician if you are in doubt as to whether the rangehood is
properly grounded.
• Failure to follow electrical requirements may result in a fire.
State of California Proposition 65 Warning (US only)
WARNING
This product contains chemicals known to the State of California to cause cancer and birth
defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
4

ELECTRICAL REQUIREMENTS

WARNING

Publicité

Table des Matières
loading

Table des Matières