OPERATING PROCEDURES

SET UP
Your stapler is fully assembled when you receive it. See the recommended air
system setup below.
Be sure that the couplers are set up so that the air hose is depressurized when
adding or removing components from the system.
Stapler

AIR SOURCE

 This flooring stapler is designed to operate on clean, dry, compressed air,
regulated at 70 to 90 PSI / 488 to 621 kPa / 4.9 to 6.1 bar. The preferred
system would include a filter, a pressure regulator, and an automatic oiler
located as close to the tool as possible (within 15 feet (5 m) is ideal). Do not
use bottled air or gases.
 Determine if it is necessary to lubricate. All compressed air contains mois-
ture and other contaminants that can harm the internal components of the
tool. An air line filter will remove most of these and significantly increase the
life of the tool. If you are using an in-line automatic oiler, check and add oil
if necessary. If an in-line oiler is not available, place 2 drops of oil into the
tool's Air Plug (2001621-47) at the beginning of each workday. More than
this will be expelled from the tool's exhaust during firing.
 Air Fitting: The flooring stapler should be equipped with a 1/4" NPT male
'quick connector'. To prevent accidental cycling even though disconnected,
the tool must always be connected to the air supply in such a way that all air
pressure in it is released when the coupling is disconnected.
CAUTION:
 All air line components (including hoses, pipe, connectors, filters, &
regulators, etc.) must be rated for a minimum working pressure of 150 PSI /
1034 kPa / 10.3 bar or 150% of the maximum system pressure, whichever is
greater.
 Disconnect the tool from the air supply before performing maintenance,
clearing a jammed fastener, leaving the work area, moving the tool to an-
other location, or handing it to another person.

PREPARING THE TOOL

1. After reading and understanding this entire manual, connect tool to air
supply.
2. Turn on the air compressor and adjust the regulator to the proper pressure
for the fastener size you are using. (See the Using the Tool below with re-
gard to adjusting this.)
12
RFS-15-1/2G-001
Oiler
Quick
Connector
Air Line
Filter
Regulator
Air Supply
!