replace the parts before wearing excessively to avoid damage to persons or property
carry out scheduled maintenance as provided in the agreement

29. Troubleshooting

DANGER! Live parts. Electrocution.
REMOVE THE ELECTRIC POWER SUPPLY BEFORE ANY OPERATION!
Problem
The cabinet
• power black-out
stops and
• master switch turned off
does not re-
start
• breakers
thermal
switches)
• electric controller faulty
The cabinet
• the cabinet is in defrosting pha-
s e
does not cool
sufficiently
• air inlets are obstructed
• the load is not distributed
evenly
• the capacitor is dirty
• the cabinet is next to air cur-
rents or heat sources
• the cabinet is not levelled
The engine is
• screws and bolts are not tighte-
noisy
n e d
• the cabinet is not levelled
Condensate
• poor room conditions
• poor air ventilation
• the window heaters do not work • check electrical connections.
• the windows are not closed pro-
p e r l y
05060165 00 15-04-2016
B e l g r a d o 2 - L o n d o n 3
Possible causes
triggered
breakers/differential
once the electrical supply has been restored, check that all the electrical
equipment in the store will restart without triggering the overload pro-
tection devices; otherwise, modify the system to differentiate the enable-
ment of the various devices.
i
If power is not restored in a short time, store the goods in a cold room to
maintain the storage temperature.
• check the cause of the black-out
• turn on the switch.
(fuses,
• check the temperature of the condensing
unit
• repair/replace the controller
• wait for defrosting to complete (about 30
min)
• r e l e a s e a i r i n l e t s
• load the goods in order (Fig.14)
• clean the capacitor chap. 24.4
• check the position of the cabinet inside the
s t o r e
• level the cabinet see
• tighten the bolts and screws
• level the cabinet
• check the position of the cabinet inside the
s t o r e
• check the operation of fans and wiring
• check heaters operation.
• close the windows properly