Télécharger Imprimer la page

Eaton Cooper Lighting IRiS P3MR Instructions D'installation page 2

Publicité

Les langues disponibles

Les langues disponibles

P3MR Recessed Housing Platform
WARNING
Risk of Electrical Shock
Disconnect power at fuse or circuit breaker before
installing or servicing.
WARNING
Risk of Fire
Supply conductors (power wires) connecting the fixture
must be rated minimum 90°C. If uncertain, consult an
electrician.
CAUTION
To avoid possible electrical shock, be sure that power
supply is turned off before installing or servicing fixture.
For your safety, read and understand instructions
completely before beginning installation.
Housing Platform Installation (Figure 1-4)
IC Platform:
The P3MR housing platform is designed
for installations where the housing comes in direct
contact with insulation (Figure 1) it can also be used in
installations where the housing platform does not come
in contact with insulation (Figure 2).
Figure 1
Figure 2
2
P3MR Recessed Housing Platform 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 www.eaton.com
WARNING
Use only elements provided by IRiS Lighting Systems.
Use of other manufacturer's reflectors or classified
Underwriter Laboratories listing and CSA Certification
could constitute a fire hazard.
NOTE
IRiS recessed luminaires (fixtures) are designed to meet
the latest NEC requirements and are UL/cUL listed in full
compliance with UL 1598. Before attempting installation
of any recessed lighting luminaire check your local
electrical code. This code sets the wiring standards for
your locality and should be carefully studied before
starting.
Platforms are airtight and meet or exceed the
performance requirements of the Council of American
Building Officials 1995 Model Energy Code (CABO MEC)
and prescriptive method used by other municipalities.
To insure proper performance, the housing platforms
must be installed with the edge of the plaster frame
collar flush to within 1/2" of bottom of the finished
ceiling. Maximum ceiling thickness is 1" with the
standard plaster frame collar (Figure 3). Use the optional
Plaster Lip extender for ceilings up to 2" thick.
1/8" Max
5/8" Thick Ceiling
Figure 3
N
ote:
Suitable with 1/2" gyp board on Housing Platform
Installation.
N
ote:
For Ceilings up to 2" thick, installer can use a
Plaster Lip Extention (part number PLE3). This
accessory is sold separately.
1/2" Max
1" Thick Ceiling