RM5310, RM5330, RM5380
Item
Description
11
Heating element AC
12
AC power connection cable
13
Housing earth (upper section)
AC power
➤ Connect the refrigerator with the mains plug to an AC socket.
DC power
Please note the following cable sizes:
– < 6 m (interior): 4 mm
– > 6 m (interior): 6 mm
– Connections D+ and S+: 1 mm
– Cable fed via drawbar (caravans only): 2,5 mm
➤ Secure the power supply line to the heating element (connections 3 and 4) with
a 15 A fuse and the supply for lighting/electronics (connections 5 and 6) with a
2 A fuse.
➤ Connect the heating element (connections 3 and 4) with the shortest possible
cable.
➤ Run the cable to the heating element (connections 3 and 4) via a relay controlled
by an ignition socket to prevent the vehicle battery from completely discharging
if the engine is switched off accidentally (fig. g, page 14).