7.9 The electric pump stops, and then
rotates in the wrong direction
Cause
There is a leakage in one
or both of the following
components:
The suction pipe.
The foot valve or the
check valve.
There is air in the suction
pipe.
7.10 The pump starts up too
frequently
Cause
There is a leakage in
one or both of the
following components:
The suction pipe.
The foot valve or
the check valve.
There is a ruptured
membrane or no air
pre-charge in the
pressure tank.
1 Introduction et sécurité
1.1 Introduction
Objectif du manuel
L'objet de ce manuel est d'apporter les
informations nécessaires pour :
Installation
Exploitation
Entretien
ATTENTION :
Lire attentivement ce manuel avant
d'installer et d'utiliser le produit. L'usage
impropre du produit peut comporter des
blessures ou des dommages matériels
et peut annuler la garantie.
AVIS :
Conserver ce manuel pour une consultation
ultérieure et veiller à ce qu'il puisse facilement être
consulté sur le site à tout moment.
1.1.1 Utilisateurs sans expérience
AVERTISSEMENT :
Ce produit est destiné à être utilisé
uniquement par un personnel qualifié.
Il sera nécessaire de prendre les précautions
suivantes :
Ce produit ne doit pas être utilisé par une
personne atteinte d'un handicap physique
ou mental, ou par une personne qui ne
possède pas l'expérience et les
connaissances requises, à moins qu'elles
24
Remedy
Repair or replace
the faulty
component.
Bleed the air.
Remedy
Repair or replace
the faulty
component.
See the relevant
instructions in the
pressure tank
manual.
7.11 The pump vibrates and
generates too much noise
Cause
Remedy
Pump cavitation
Reduce the required flow
rate by partially closing the
on-off valve downstream
from the pump. If the
problem persists check the
operating conditions of the
pump (for example height
difference, flow resistance,
liquid temperature).
The motor
Contact the local sales and
bearings are
service representative.
worn.
There are
Contact the local sales and
foreign objects
service representative.
inside the pump
Impeller rubs on
Contact the local sales and
the wear ring
service representative.
Coupling
Check the coupling
misaligned
alignment.
Flexible
Check and replace the
elements of the
relevant parts if there is any
coupling worn
sign of wear.
For any other situation, refer to the local sales
and Service representative.
aient reçu des consignes sur l'utilisation de
l'équipement et sur les risques associés ou
soient surveillées par une personne
responsable.
Les enfants doivent être surveillés afin de
s'assurer qu'ils ne jouent pas sur le produit
ou autour de celui-ci.
1.2 Terminologie et symboles de
sécurité
A propos des messages de sécurité
Il est extrêmement important de lire, comprendre
et respecter attentivement les consignes de
sécurité et la réglementation avant d'utiliser ce
produit Xylem. Ces consignes sont publiées pour
contribuer à la prévention des risques suivants :
accidents corporels et mise en danger de
la santé
Dégâts au produit et aux alentours
Dysfonctionnement du produit
Niveaux de risque
Niveau de risque
DANGER :
AVERTIS-
SEMENT :
Indication
Une situation
dangereuse qui, si
elle n'est pas évitée,
entraînera la mort ou
des blessures graves.
Une situation
dangereuse qui, si
elle n'est pas évitée,
pourrait entraîner la
mort ou des
blessures graves.

Publicité

Table des Matières
loading