12 EC declaration of conformity (original)

Designation:
Type:
Generation:
Year of design:
en
We declare, on our sole responsibility, that this
product complies with the following directives and
standards:
75/324/EEC,
EN ISO 12100, EN 13752‑1:2008‑12, EN 50081‑2,
EN 1127‑1, EN 417, ISO 8662‑11 AMD 1:2001-12,
EN
792‑13:A1:2008‑09,
64/548/EEC, EN 55011:1998+A1:1999, CISPR 11:2003,
A1:2004, IEC 61000‑6‑2:2005, EN 61000‑6‑2:2001,
IS1:2005, IEC 61000‑6‑3:1996, EN 61000‑6‑3:2001,
IEC
61000‑4‑2:1995,
IEC 61000‑4‑8:1993: A1:2000, 2006/42/EC, 2011/65/EU.

13 Health and safety of the operator

13.1 Noise information

Gas-actuated fastening tool
Type
Model
Caliber
Power regulation
Application
Declared measured values of noise characteristics according to 2006/42/EC Machinery Directive in conjunction
with DIN EN 15895
Noise (power) level, L
Emission sound pressure level at the workplace,
L
2
pA, 1s
Peak sound pressure emission level, L
1 ± 2 dB (A)
2 ± 2 dB (A)
3 ± 2 dB (C)
Operation and set-up conditions: Set-up and operation of the pin driver in accordance with E DIN EN 15895-1 in the
semi-anechoic test room of Müller-BBM GmbH. The ambient conditions in the test room conform to DIN EN ISO 3745.
Testing procedure: Enveloping surface method in anechoic room on reflective surface area in accordance with
E DIN EN 15895, DIN EN ISO 3745 and DIN EN ISO 11201.
NOTE The noise emissions measured and the associated measurement uncertainty represent the upper limit for the
noise values to be expected during the measurements.
Variations in operating conditions may cause deviations from these emission values.

14. FCC statement

This device complies with Part 15 of the FCC Rules and to RSS-210 of Canada.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
26
Gas-driven fastening tool
GX 120‑ME
91/155/EEC,
64/548/EEC,
EN
60529:2000‑09,
IEC
61000‑4‑3:2006,
1
WA, 1S
pC, peak
Hilti Corporation, Feldkircherstrasse 100,
FL‑9494 Schaan
01
2007
Norbert Wohlwend
Head of Quality & Processes Manage-
ment
BU Direct Fastening
04/2013
Technical documentation filed at:
Hilti Entwicklungsgesellschaft mbH
Zulassung Elektrowerkzeuge
Hiltistrasse 6
86916 Kaufering
Deutschland
GX 120-ME
Series
GC 22
+
Fastening 1 mm sheet metal to concrete (C40) with the
X-ECT
106 dB (A)
102 dB (A)
137 dB (C)
3
Tassilo Deinzer
Head of BU Direct Fastening
BU Direct Fastening
04/2013