• Ensure that parts of the body, hair or items of clothing cannot be trapped by
the motion parts.
• Never touch moving parts.
Caution! The shaker still runs after the cover has been opened. Wait
for it to stop running.
(Risk of being crushed, shocked or cut, see figure illustrating danger points).
• Should vessels break during operation or the media be spilt, interrupt the shak-
ing process immediately, remove any vessel residue and clean the appliance.
Danger of being burnt! Exercise caution when touching housing
components and attachments. They may become hot. Watch for
residual heat after appliance has been switched off.
• Pay attention to the risk of:
- flammable materials
- glass breakage
- flammable media with low boiling temperatures
- level of medium which is too high
- biological and microbiological materials.
• All accessories and vessels in place for the shaking process must be firmly
secured.
• Shaking vessels which are not properly secured could get damaged or be
projected out, thus causing injury. It is essential to regularly check that the
vessels to be shaken and the attachments are firmly secured, especially before
using the appliance again.
• If you notice that the device is not running smoothly, the speed must always be
reduced until no more uneveness occurs in the operation.
• Because of improper loading and the position of the center of gravity, dynamic
forces may arise during the agitation process that cause the shaker to move
about on the table. For restrictions of load capacity and material weight during
high shaking frequencies, please see the description in the "Attachments"
section.
• Additional hazards to the user may occur if inflammable materials are used
during the shaking operation.
• Furthermore, the shaking unit may only be used to stir those materials or
material mixtures that the user knows will not react dangerously to the extra
energy produced by the stirring. This also applies to extra energy by means of
solar radiation during the shaking procedure.
• The shaker may not been used in explosive atmospheres, for mixing dangerous
substances or under water.
• When using an external temperature sensor, it must always be in the medium.
Immerse the external temperature sensor at least 20mm into the medium.
• The safety of the user cannot be guaranteed if the appliance is operated
with accessories that are not supplied or recommended by the manufacturer
or if the appliance is operated improperly, contrary to the manufacturer's
specifications.
• Caution! Never process and heat up any media that has a flash point higher
than the adjusted safe temperature limit that has been set.
The safe temperature limit must always be set to at least 25 °C lower than the
fire point of the media used.
• When servicing, the wiring selected by IKA must be set up again!
• Avoid allowing objects to push or strike the agitation table.
• Keep a minimum distance of 100 mm from the appliance on all sides.