Non-Locking Types
Snap-Tite - Aluminum (AL), Brass (BR), Stainless Steel (SST)
Foster - Steel (S), Stainless Steel (SST)
Hansen - Brass (BR)
Non-Locking Types with Valve in Plug
Foster - Brass (BR)
Hansen - Stainless Steel (SST)
7
Donning
WARNING!
• Obey the instruction in this section to make sure that the respirator operates correctly before going into a hazardous
atmosphere.
• If the respirator does not operate correctly as described in this section, remove the respirator from service. Make
sure an MSA trained and certified repair technician corrects the unsatisfactory condition before returning the
respirator to service.
• If you have a beard, gross sideburns, or similar physical characteristics that prevent direct contact between your skin
and the sealing surface of the facepiece, this device may not seal properly with your face (refer to NFPA 1500 and
OSHA 29 CFR 1910.134). An incorrect facial seal can let contaminants leak into the facepiece, decreasing or
removing respiratory protection. Do NOT use this device if such conditions exist.
• Do a test of the face-to-facepiece seal before each use.
• Make sure the correct nosecup is installed in the facepiece.
• Individuals who wear eyeglasses must use the G1 spectacle kit to guarantee a correct fit. Ordinary eyeglasses
cannot be worn under the facepiece.
• Only remove the facepiece in a safe, nonhazardous, nontoxic atmosphere.
Failure to follow these warnings can result in serious personal injury or death.
US
PremAire® Cadet Escape G1
7 Donning
15