INSTALLATION OF THE INDOOR UNIT
After having connected the pipe according to the instructions,
install the connection cables. Now install the drain pipe. After
connection,lag the pipe, cables and drain pipe with the insula-
ting material.
1. Arrange the pipes ,cables and drain hose well.
2. Lag the pipe joints with insulating material, securing it with vinyl tape.
3. Run the bound pipe, cables and drain pipe through the wall hole
and mount the indoor unit onto the upper part of the mounting plate
securely.
4. Press and push the lower part of the indoor unit tightly against the
mounting plate
conection cable
conection cable 1
(for heat pump)
INSTALLATION MANUAL - INSTALLATION OF THE OUTDOOR UNIT
● The outdoor unit should be installed on a solid wall nd fastened securely.
● The following procedure must be observed before connecting the pipes and connecting cables: decide which
is the best position on the wall and leave enough space to be able to carry out maintenance easily.
● Fasten the support to the wall using screw anchors which are particularly suited to the type of wall;
● Use a larger quantity of screw anchors than normally required for the weight they have to bear to aviod vibrati-
on during operation and remain fastened in the same position for years without the screws becoming loose.
● The unit must be installed following the national regulations.
OUTDOOR UNIT CONDENSED WATER DRAINAGE
(ONLY FOR HEAT PUMP MODELS)
The condensed water and the ice formed in the outdoor unit
during heating operation can be drained away through the
drain pipe
1. Fasten the drain port in the 25mm hole placed in the part
of the unit as shown in the picture.
2. Connect the drain port and the drain pipe. Pay attention
that water is drained in a suitable place.
refrigerant pipe
probe cable (for
heat pump)
EN
covered by
vinyl tape
insulation sleeve
refrigerant pipe
condensed water
drain pipe
24
v1• 11.11.2020
mounting plate
drain port
drain pipe
KEN002VAC