Mounting and
operating instructions
7.2

Possible Settings and Operating Modes

· Set the switching point or switching window
· Scale the analogue output
· Set the operating mode (Speed Mode / Averaging Mode )
· Set the switching type (N.O. / N.C)
· Reset the sensor to the factory state
· Laser off and measured value hold (via electrical connection)
· Lock buttons
and
7.3

Factory State

· Switching output:
Switching output is active when the object is in the operating range and reliably detected. Switching type = N.O.
· Analogue output (4 ... 20 mA):
4 mA = end of operating range, 20 mA = beginning of operating range
· Operating mode = speed mode (shortest response time)
· Operation
= free running (normal mode)
7.4

Make settings

7.4.1

Activating the Set Mode (conf)

Push the buttons
and
(LED flashes when time lock open and Set mode activated).
7.4.2

Setting the Sensor

No. LED pattern Action
Description
1a
Q
Set switching point for switching output Q
QA
OK
A
Position the object at the desired switching point. The „OK" LED must light.
V
N
FS
Push
C
Push
LED (red) flashes with 1 Hz.
Exit the Set menu (
go to the next setting with
1b
Set the switching window for switching output Q
Q
QA
A
OK
Position the object at the desired first switching window limit. The „OK" LED
V
N
FS
must light.
C
Push
Push
LED (red) flashes with 1 Hz.
Position the object at the desired second switching window limit. The „OK"
LED must light.
Push
the object is detectable and in the operating range. The „ZA" LED lights for
confirmation for as long as
Exit the Set menu (
go to the next setting with
Information
If the object was not moved after teaching the first switching window limit, a minimum switching window
(1 % of the operating range) is laid around the teach point.
FT 50 RLA Distance sensor - GB - 068-13799 - 27.07.2010-01
(via electrical connection)
simultaneously for 3 s (or longer) until the LED BA (green) flashes
until the „Q" LED lights.
once. If the object is detectable and in the operating range, the „ZA"
+
) or
.
until the „Q" LED lights.
once. If the object is detectable and in the operating range, the „ZA"
once. The distance is saved as the second switching window limit if
is pushed.
+
) or
.
Factory setting
Switching window
over the whole
operating range,
i.e. switching
output is active
when the object
is in the operating
range and reliab-
ly detected.
19