L. G. B. 55005 Instructions De Service page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

grammed properly, it will move a
very short distance.
- Press the emergency stop but-
ton again to resume operation.
With a 55010 Train Mouse, you
can program addresses 1 to 8
directly using the Central Station:
- Remove all other locos from the
tracks.
- Set the Train Mouse speed con-
trol to 0.
- Select the loco address with the
Train Mouse address selector.
- Press and hold the emergency
stop button on the Train Mouse.
- At the same time, press the
Reset button on the Central Sta-
tion.
- Press the function button on the
Train Mouse.
- If the loco has been pro-
grammed properly, it will move a
very short distance.
- Release the emergency stop
button.
- After the Train Mouse LED has
flashed three times, press the
emergency stop button again to
resume operation.
Hints:
- Train Mouse address 8 is pro-
grammed and controlled as
address 00 with other MTS
throttles.
- Locos that are always connect-
ed (for example, F7 A-B-A com-
binations)
grammed to the same address.
- To program loco addresses 16
to 22, you need the 55015 Uni-
versal Remote or the 55045
MTS PC Decoder Programming
Module and a programming
track. For more information, see
the instructions for these MTS
components.
- With
the
Remote, loco address 00 is pro-
grammed as 23.
- With a Loco Remote, you can
program MTS Switch Decoder
addresses 1-15 in the same way
as loco decoder addresses:
Remove all locos from the
tracks. Insert a programming
jumper in the switch decoder
you want to program. Program
the switch decoder as described
above for loco decoders.
should
be
55015
Universal
ID NUMBER
Many MTS components have ID
(identification) numbers. ID num-
bers should not be duplicated.
(Exception: Multiple 55055/55056
Wireless Receivers on a layout
always should be programmed to
the same ID number.) For more
information, see the instructions
for the individual MTS compo-
nents.
The MTS Central Station recog-
nizes 7 ID Numbers (1-7, 1 and 2
have priority). For complex lay-
outs, we recommend selecting ID
1 for the 55060 MTS Computer
Interface, ID 2 for 55075 MTS
Train Detection Modules and
55070 MTS Feedback Interfaces,
while all other components can
receive ID Numbers between 3
and 7.
TROUBLE SHOOTING
- Locomotives do not work reli-
ably.
- Is the track dirty? Dirty track
can prevent commands and
power from reaching the locos.
Clean dirty tracks with a 20670
Track Cleaning Locomotive
(with decoder), 50040 Track
Cleaning Block, 50050 Track
Cleaning Attachment or 50010
Smoke and Cleaning Fluid.
- When using a Train Mouse, is
pro-
the correct operating mode
selected?
- The LEDs on the Central Sta-
tion are off. The system is not
receiving power.
- Is the power supply plugged in?
- Is the power supply properly
connected to the Central Sta-
tion?
- If you use a DC power supply:
Is the polarity of the power
supply correct? (To reverse the
polarity, reverse the power
pack's direction or swap the
wires to the Central Station.)
- The Central Station LED flash-
es red and the LED on the
MTS throttle flashes. There is
a short circuit.
- Has a train derailed?
- Is there a metal object lying
across the track?
- Is there a faulty connection or
cable?