4.5.2 Horizontal installation
!
NOTE: A plumbing trap is required to keep the cell flooded with water when the dosing acid pump
washes the cell during the circulation pump downtime. Create the trap so the acid injected by the
dosing acid pump will be focused on the cell and not flow back to the pool or equipment set.
!
WARNINGS
Disconnect ALL power before work commences.
Open the control box lid to make sure the unit is turned OFF.
It is recommended to wear rubber or polyethylene protective gloves and safety glasses. It is also
advisable to protect your clothes.
Make sure the pool's machine room is properly vented to avoid damage from acid vapors.
Under no circumstances should the machine room be used to store equipment, furniture, sports gear
or any other equipment that is not related to the pool, including spare acid containers. The machine
room must be aired and vented prior to entering it.
Acid container must be stored inside a spill containment vessel (a basin to hold acid in case of
overflow or tipping of the acid container).