Télécharger Imprimer la page

Klein Tools CL710 Manuel D'instructions page 2

Les langues disponibles

Les langues disponibles

ENGLISH
GENERAL SPECIFICATIONS
Klein Tools CL710 is an automatically ranging true root mean square
(TRMS) digital clamp-meter that measures AC/DC current via the
clamp, measures AC/DC voltage, resistance, continuity, frequency,
capacitance, and tests diodes via test leads. It also features a Low
Impedance (LoZ) mode for identifying and eliminating ghost or stray
voltages, transflective reverse-contrast display, and lighted dial.
• Environment: Indoor: Do not expose to moisture, rain or snow.
• Operating Altitude: 6562 ft. (2000m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 32° to 122°F (0° to 50°C)
• Storage Temp: 14° to 140°F (-10° to 60°C)
• Accuracy: Values stated at 65° to 83°F (18° to 28°C)
• Auto Power-Off (APO): After 5 minutes of inactivity (unless
disabled)
• Dimensions: 9.06" × 3.47" × 1.65" (230 × 88 × 42 mm)
• Weight: 13 oz. (369g) including batteries
• Calibration: Accurate for one year
• Standards: IEC EN 61010-1, 61010-2-032.
Conforms to: UL STD 61010-1, 61010-2-032.
Certified to: CSA STD C22.2 #61010-1, 61010-2-032.
5000573
• Pollution degree: 2
• Accuracy: ± (% of reading + # of least significant digits)
• Drop Protection: 6.6 ft. (2m)
• Safety Rating: CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building's low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building's
low-voltage MAINS installation.
• Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
2
ELECTRICAL SPECIFICATIONS
Function Range Resolution
600mV
0.1mV
6.000V
1mV
AC
Voltage
60.00V
10mV
(V AC)
600.0V
100mV
1000V
1V
600mV
0.1mV
6.000V
1mV
DC
Voltage
60.00V
10mV
(V DC)
600.0V
100mV
1000V
1V
Input Impedance: 10MΩ
Maximum Input: 1000V AC RMS or 1000V DC
NOTE: All AC voltage ranges are specified from 5% to 100% of range.
60.00A
AC Current
(A AC)
600.0A
60.00A
DC Current
(A DC)
600.0A
Frequency Range: 50 to 60Hz
Function
Range
600.0Ω
6.000kΩ
60.00kΩ
Resistance
600.0kΩ
6.000MΩ
60.00MΩ
Maximum Input: 1000V AC RMS or 1000V DC
60.00nF
600.0nF
6.000µF
Capacitance
60.00µF
600.0µF
6000µF
Maximum Input: 1000V AC RMS or 1000V DC
Accuracy
LoZ Accuracy
±(1.8% + 8 digits)
±(2.5% + 8
±(1.0% + 3 digits)
±(1.2% + 5 digits)
±(0.5% + 5 digits)
±(2.0% + 5
±(0.8% + 3 digits)
±(1.0% + 3 digits)
Frequency Range: 50 to 400Hz
10mA
±(2.0% + 8 digits)
100mA
±(2.0% + 5 digits)
10mA
±(2.0% + 8 digits)
100mA
±(2.0% + 5 digits)
Resolution
Accuracy
0.1Ω
0.01kΩ
±(1.2% + 5 digits)
0.1kΩ
1kΩ
10kΩ
±(2.0% + 10 digits)
0.01nF
±(3.5% + 10 digits)
0.1nF
0.001µF
±(3.0% + 5 digits)
0.01µF
0.1µF
1µF
±(3.5% + 5 digits)
digits)
digits)
3
loading