When using the unit in a pond, please take the required action to ensure that no inhabitants of the pond will be
sucked in.
The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.
3.

Technical Data

Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate (Q
)
max
Max. pressure
1)
Max. delivery height (H
)
max
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature (T
)
max
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
2)
Min. self-priming level (A)
2)
Min. suction level (B)
2)
Cut-in level (C)
2)
Cut-out level (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
4.

Scope of delivery

The scope of the delivery of this product includes:
One pump with connection cable, two connection ports, one reducing part, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5.

Installation

5.1.

General installation information

During the entire process of installation, the device must not be connected to the electrical
mains.
The pump and the entire connection system have to be protected from frost.
8
Maxima 300 SX
230 V ~ 50 Hz
700 Watt
IP 68
47.80 mm
, male
(1 ½ ")
18,000 l/h
0.8 bar
8 m
5 m
30 mm
35° C
30, evenly distributed
10 m
H07RN-F
7.0 kg
110 mm
50 mm
390 mm
200 mm
20 x 17 x 36 cm
30116
2