4. PATTERN SET – SAVE
To save the filled data, move joystick to the rightwards when the cursor is on SAVE. This
may take several seconds. Then the cursor moves to the following pattern no in order to
prepare next pattern.
5. PATTERN SET – EXIT
Move joystick to the right to return to main menu.

8.9 Alarm Set

4 Alarm inputs are available and each of them is able to activate a preset, group tour or pattern.
ALARM SET
ALARM NO
ALARM INPUT : OFF
ALARM ACT
SAVE
EXIT
1. ALARM SET – ALARM NO.
Up to 4 alarm inputs are selectable by moving joystick right or left when cursor is on ALARM
NO. This number represents the corresponding alarm input on the rear side of speed dome.
2. ALARM SET – ALARM INPUT
The alarm inputs supports 3 different connection states: NC (Normally Close), NO (Normally
Open) or OFF (disabled)
The default setting is OFF
3. ALARM SET – ALARM ACT
Alarm inputs can activate various surveillance modes. Preset number from1~64 and
100~200, Group tour 1 to 8 and Pattern 1 to 8 are available. Move joystick right or left to
select desired preset position, group tour no. or pattern no.
4. ALARM SET – SAVE
After setting the alarm input state and activation, move joystick rightwards when the cursor is
on SAVE in order to save changes. After saving, the cursor jumps to the following alarm no.
to set the next alarm.
5. ALARM SET – EXIT
Move joystick to the right to return to main menu.
* Before activating the Alarm, the user must set ALARM ENABLE at DOME SET – ALARM
: 01