Suitable measures include regular maintenance and care of
the tool and the insertion tools, regular breaks as well as prop-
er planning of the working process.
Warning!
In case of extended working periods, the operating personnel
may suffer circulatory disturbances in their hands (vibration
white finger) due to vibrations.
Raynaud's syndrome is a vascular disease that causes the small
blood vessels on the fingers and toes to cramp in spasms. The
affected areas are no longer supplied with sufficient blood
and therefore appear extremely pale. The frequent use of vi-
brating devices can cause nerve damage in people whose
circulation is impaired (e.g. smokers, diabetics).
If you notice unusual adverse effects, stop working immedi-
ately and seek medical advice.
Observe the following information to reduce hazards:
• Keep your body and especially your hands warm in cold
weather.
• Take regular breaks and move your hands to promote cir-
culation.
• Ensure as little vibration as possible at the device via regu-
lar maintenance and stable parts on the machine.
8. Unpacking
1. Open the packaging and carefully remove the device.
2. Remove the packaging material, as well as the packag-
ing and transport safety devices. Remove the transport
safety devices with an open-end spanner AF 10 mm (not
included in the scope of delivery).
3. Check whether the scope of delivery is complete.
4. Check the device and accessory parts for transport dam-
age. In the event of complaints the carrier must be in-
formed immediately. Later claims will not be recognised.
5. If possible, keep the packaging until the expiry of the war-
ranty period.
6. Familiarise yourself with the device by means of the oper-
ating manual before using for the first time.
7. With accessories as well as wearing parts and replace-
ment parts use only original parts. Spare parts can be
obtained from your specialist dealer.
8. When ordering please provide our article number as well
as type and year of manufacture for your equipment.
m DANGER
The device and the packaging are not children's
toys! Do not let children play with plastic bags,
films or small parts! There is a danger of choking
or suffocating!
9. Layout
m WARNING!
Danger of injury and damage!
The use of incorrect spare parts and accessories can lead to
injuries and damage. These could come loose and be flung
away. They can also reduce the power of the machine.
- Only use original spare parts and accessories from the
manufacturer. Original spare parts or accessories can be
obtained from your specialist dealer.
- Failure to do so may reduce the power of the machine and
parts may come loose.
- Failure to observe this will invalidate the manufacturer's
warranty.
NOTE!
Due to the heavy weight of the machine, we rec-
ommend installation by at least two people.
Some parts of the delivery come disassembled. You require
the following for assembly:
• Open-end spanner AF 13 mm (mounting fuel tank)
• Needle-nosed pliers (mounting fuel tank)
• Open-end spanner AF 16 mm (assembly of protective
frame and adapter plates)
• Open-end spanner AF 8 mm (mounting throttle)
• Open-end spanner AF 10 mm (mounting throttle)
The assembly tool is not included in the scope of delivery.
9.1 Mounting the protective frame (2) (Fig. 3)
1. First remove the four hexagonal bolts M10x25 (B), the
spring washer and washers from the adapter plates (21)
on both sides.
2. Fasten the protective frame (2) to the adapter plates (21)
on both sides using four hexagonal bolts M10x25 (B), the
spring washers and washers.
3. Tighten the hexagonal bolts (B) with an open-end spanner
AF 16 mm.
9.2 Fitting the fuel tank (5) (Fig. 4, 5)
1. Fasten the fuel tank (5) to the mounting plate of the protec-
tive frame (2) with two hexagonal bolts (D), two washers
M8 and two locking nuts M8.
2. Tighten the hexagonal bolts (D) with an open-end span-
ner AF 13 mm.
3. Push the fuel hose onto the fuel valve on the fuel tank (19).
Secure the fuel hose using the hose clamp (C) to prevent
slipping. Use needle-nosed pliers for this.
9.3 Fitting the throttle (6) (Fig. 2, 6)
1. Fasten the throttle (6) to the protective frame (2) using the
fastening clip, two hexagonal bolts M6x30 and two self-
locking nuts M6.
2. Tighten the hexagonal bolts and nuts with an open-end
spanner AF 10 mm and AF 8 mm.
3. Fasten the throttle cable to the protective frame (2) using
the cable ties (F) provided.
10. Before commissioning
m ATTENTION!
Always make sure the machine is fully assem-
bled before commissioning!
GB/IE/NI/CY/MT
9