CALIBRATION MODE

10
10.1 - WITH AN KNOWN WEIGHT
a - Turn on the scale and be sure it is zeroed.
b - Keep pressing
tion weight.
Here, required weight is 6000g for calibration.
c - Put a weight same as what exactly shown in the UNIT.
Press the
The scale will stop blinking and return to normal counting mode.
10.2 - WITH AN UNKNOWN WEIGHT
a - Turn on the scale and be sure it is zeroed.
b - Keep pressing
tion weight.
c - Use the numeric keys to input a calibration value.
Press the
The scale will stop blinking and return to normal counting mode.
!

ERROR MESSAGES

11
E1
E2
E3
E4
--OL--
--------
34
key.
key.
EPROM database
The initial zero is outside the range
of the factory setting for zero
The low limit value is set higher
than the high limit value
The address of storing unit weight
is out of the address range
Low battery charge
Load exceeds scale capacity
System is busy
A value exceeds the display range
Can only be done in kg
key until the following. Display shows the calibra-
key until the following. Display shows the calibra-
Recalibrate the scale.
1. Check if there is something on the pan or something
touches the top body when switch on the scale, move the
load and switch on again.
2. Recalibrate the scale.
Reset the limit values
Input new address
Recharge the battery
Reduce the load on the pan
Just wait
Cancel some operation item