Step 2: Wipe Out Inside Of Washtub; Step 3: Connect Fill Hoses; Water Supply Requirements - Alliance Laundry Systems Metered Models Manuel D'installation Et De Fonctionnement

Table des Matières
Les langues disponibles

Les langues disponibles

Installation

Step 2: Wipe Out Inside of Washtub

Prior to first wash, use an all purpose cleaner or a
detergent and water solution and a damp cloth to
remove shipping dust from inside of washtub.
Figure 3
8
W396I
W396I
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Step 3: Connect Fill Hoses

WARNING
Under certain conditions, hydrogen gas
may be produced in a hot water system
that has not been used for two weeks or
more. HYDROGEN GAS IS EXPLOSIVE. If
the hot water system has not been used
for such a period and before using the
washer, turn on all hot water faucets and
let the water flow from each for several
minutes. This will release any
accumulated hydrogen gas. The gas is
flammable. Do not smoke or use an open
flame during this time.
Mixing Valve Flow Rates - MDC Models without
Small Load Switch
Pressure
HOT
(psi)
gallons per
minute
(liters per
minute)
2.4
35
(9.1)
3.5
55
(13.2)
Table 1
Mixing Valve Flow Rates - Coin Slide Operated,
Nonmetered, MDC Model with Small Load Switch
Pressure
HOT
(psi)
gallons per
minute
(liters per
minute)
4.22
35
(15.97)
5.24
55
(19.84)
Table 2

Water Supply Requirements

Water supply faucets must fit standard 19.1 mm
(3/4 inch) female garden hose couplings. DO NOT
USE SLIP-ON OR CLAMP-ON CONNECTIONS.
NOTE: Water supply faucets should be readily
accessible to permit turning them off when washer
is not being used.
Water level in washer is controlled by a water level
switch.
W029
COLD
WARM
gallons per
gallons per
minute
minute
(liters per
(liters per
minute)
minute)
4.5
7.15
(17.0)
(27.1)
6.2
9.2
(23.5)
(34.8)
COLD
WARM
gallons per
gallons per
minute
minute
(liters per
(liters per
minute)
minute)
5.37
8.65
(20.33)
(32.74)
6.85
10.83
(25.93)
(41)
201940

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Nonmetered modelsW446i

Table des Matières