PERFORMANCE DATA
Important Notice: Read performance data and compare the capabilities
of the system with your actual water treatment requirements. It is
recommended that the supply water be tested, before installing a water
treatment system, to determine your water treatment needs.
TEST CONDITIONS
Flow Rate
F2000-B2B ..............................................................0.60 gpm (2.27 L/min)
FILTER CAPACITY
F2000-B2B ................................................................. 675 gallons (2555 L)
Inlet Pressure ...................................................................... 60 psi (4.1 bar)
Temperature ................................................... 68°F +/- 5°F (20°C+/- 2.5°C)
Testing was performed under standard laboratory conditions, actual
performance may vary.
Operating Requirements for F2000-B2B System:
Pressure ............................................................ 40-100 psi (2.75-6.89 bar)
Temperature ............................................................40-100°F (4.4–37.8°C)
F2000-B2B SYSTEM INSTALLED WITH F2B2-RC2 FILTER
CARTRIDGE SET
This system has been tested according to NSF/ANSI 42 and 53 for reduction
of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water exiting the system, as
specified in NSF/ANSI 42 and 53.
MODEL F2000-B2B
Influent Challenge
Substance
Concentration
Standard 42
Chlorine Taste
2.0 mg/L±10%
& Odor
Particulates
at least 10,000
(0.5-<1uM)
particulates/mL
Class 1*
Standard 53
Cysts **
Minimum 50,000/L
Atrazine
0.009 mg/L ± 10%
Lead (pH 6.5)
0.15 mg/L ± 10%
Lead (pH 8.5)
0.15 mg/L ± 10%
Total PFAS
0.00216 mg/L +/- 20%
Flow Rate = 0.6 gpm (2.2 L/min); Capacity = 675 gallons (2555 L) or 12 months
Testing was performed under standard laboratory conditions, actual performance
may vary.
* Reduces particles as small as 0.5-1 micron in size by mechanical means
** NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia
by mechanical means.
EPA Est. 082989-CHN-001
Max. Permissible
Reduction
Minimum
Product Water
Requirements
Reduction
Concentration
-
≥50%
-
-
>85%
-
-
99.95%
99.97%
0.003 mg/L
-
90.5%
0.010 mg/L
-
99.3%
0.010 mg/L
-
99.3%
0.00002 mg/L
-
99.34%
Average
Reduction
The model F2000-B2B is Tested and Certified by NSF
95.9%
International against NSF/ANSI Standard 42, 53, and
CSA B483.1 for the reduction of substances specified on
the Performance Data Sheet.
97.9%
99.99%
93.7%
The model F2000-B2B is certified by IAPMO R&T against
99.9%
NSF/ANSI 53 for the reduction of Total PFAS.*
99.6%
*The test mixture for total PFAS is made up of PFOA (500 ppt), PFOS
99.7%
(1,000 ppt), PFHxS (300 ppt), PFNA (50 ppt), PFHpA (40 ppt), PFBS (260
ppt), and PFDA (10 ppt). This system meets the 20 ppt requirement for
Total PFAS.
FRESHPOINT F2000-B2B Filtration System Installation and Operation Manual • 9