Cleaning Instructions And Care Of Your Rapport™ Classic V.t.d - Owen Mumford Rapport Classic Mode D'emploi

Masquer les pouces Voir aussi pour Rapport Classic:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3
When the desired erection has been achieved, continue to hold
the tube tightly against your body. Hold the tube with one hand,
still pushing it against your body and with the other hand, ease the
constriction ring off the transfer sleeve and onto the base of your penis.
Always position the constriction ring with the handles to the top and
bottom while on the base of your penis. This will help with ejaculation
and easier removal. (Fig.8)
Because of the special shape of the transfer sleeve, when the
constriction ring is eased out of the flat groove it will then slip easily
off the transfer sleeve and onto the base of your penis.
Some vacuum pressure may be lost during this transfer, but you will
still need to press the release valve to lower the vacuum pressure and
enable you to remove the penile tube. (Fig.9)
If you find that placing the constriction ring onto your penis is difficult,
try releasing a little of the vacuum by pushing the penile tube away
from your body slightly then rolling the ring off the transfer sleeve.
4
With a constriction ring in place, a lasting erection should now be
maintained and sexual intercourse can be accomplished.
NOTE:
If a condom is to be worn, it should be put on as a last step.
Do not wear a condom during the vacuum process. (Fig.10)
5
To remove the constriction ring after intercourse, simply grasp the outer
handles to stretch the central ring. As the blood is released from the
penis it will decrease in size and the ring may be easily removed.
9
8
12
10
Cleaning Instructions and Care of your
Rapport™ Classic V.T.D.
1
The Constriction Rings
After each use, the constriction ring should be washed with mild
soap in warm water, rinsed well and dried thoroughly. Return the
ring to its bag.
Make sure you only use water soluble lubricating jelly with the constriction
rings. Your rings should last longer if cared for properly.
2
The Penile Tube and Transfer Sleeve
After each use, the penile tube and transfer sleeve should be washed
thoroughly with a mild soap in warm water. Rinse and dry well before
replacing them into the carrying bag.
3
The Vacuum Pump
Very little maintenance is needed for the vacuum pump, but we
recommend that you occasionally wipe the vacuum pump with a damp
cloth to remove any dirt or lubrication.
pump in water, as this may cause handle to stick and it will not
be possible to create a vacuum.
Please take care when wiping the underside of your vacuum pump as the
non return valve (3 pronged rubber valve) can be pushed into the piston
chamber with only a slight force.
valve is not in position, no vacuum
Non return valve
will be achieved.
It will be necessary from time to
time to lubricate the O-ring on the
pump head, particularly if you are
finding it difficult to attach or remove
the pump head to and from the
penile tube.
After cleaning the pump head apply a little petroleum jelly to the O-ring
(the coloured band) making sure you smear the lubricant all the way
around the O-ring. This will ensure a total seal between the pump head
and the penile tube and maintain the vacuum inside the penile tube.
NOTE:
with petroleum jelly is the ONLY use of
petroleum jelly.
Do not allow petroleum jelly to come
in contact with the constriction rings as
it could damage them.
Do not immerse the vacuum
If this
This lubrication of the O-ring
13