KSK
9
Troubleshooting
Malfunction
Cause
Coupling broken
– Overloading
– Too much offset
Connecting shaft
Connecting shaft does not lie
slides through /
securely in the coupling
jerky movement
Clamping screws loose
Grease in the clamping
connections
System overloaded
Scraping noises
Too much offset
during positioning
Components rub against other
components
y-axis tilted
Coupling defective (broken), shaft
during positioning
breaks through
Tab. 3
Festo – KSK – 1503d English
Remedy
Replace coupling, observe maximum limits
Observe minimum dimension B
(è 5.2 Implementing installation)
Tighten clamping screws
1. Loosen the clamping connection con
cerned, remove and replace the dam
aged parts
2. Remove grease from contact surfaces
3. Reassemble the connecting shaft
Observe maximum limits
Readjust slide position without offset
(è 5.2 Implementing installation)
Create spaces
Replace coupling
25