Technical Features - Bartscher 600 Série Mode D'emploi

Bacs à frites électriques
Masquer les pouces Voir aussi pour 600 Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The following instructions for set up and functioning refer to electric appliances. The data plate (fig.
2 – p.2), with all the information to refer to regarding the appliance, is situated inside the right or
left side of the control panel, depending on the model.
The appliances have been checked in accordance with the European directives below.
2014/35/UE
- Low Tension (LVD)
2014/30/UE
- Electromagnetic Compatibility (EMC)
2006/42/EC
- Machinery directive
2011/65/CE
- Rohs
and the particular reference norms.
Declaration of compliance
The manufacturer declares that the appliances of their production are compliant with the above
mentioned EEC directives and requires that installation be done observing the norms in force,
regarding particularly the system for letting out fumes and air exchange.
Electric chip scuttle
Sturdy structure in steel placed on four feet, which make it possible to regulate the height. The
external coating is in Chrome-Nickel 18-10 stainless steel.
The (removable) vat is made of stainless steel and it is supplied with a properly moulded ramp, so
that oil can be easily drained from the vat. Heating is obtained through a special ceramic infrared
radiator activated by a power regulator, thus allowing regulating the functioning frequency of the
heating element. An automatically rearmed safety thermostat ensures that the temperatures
measured on the metal surfaces where the heating element is placed do not exceed the limits.
Place (fig.4 – page 2)
It is advisable to install the appliance in a well ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 50 mm from the side and back walls
must be observed. In the event that it is not possible to observe this distance, protective measures
must be taken (e.g. use of sheets of refractory material) which ensure that the temperature of the
walls is within the established safety limits.
Installation
Installation operations, voltage conversions to other than the original, starting up the installation or
appliance, ventilation and maintenance has to be done following the manufacturer's instructions and
observing the norms in force, by qualified personnel, in compliance with the following provisions
(GB):
 Health and Safety at Work Act, 1974

TECHNICAL FEATURES

DESCRIPTION OF APPLIANCES
PROVISIONS FOR INSTALLATION
Pag. 19/31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

K6esp05tt

Table des Matières