IMPORTANT!
If you have purchased this meter as part of
a "Kit", the meter flange base is drilled with 4 holes.
allows
the meter
to be used with 300 and (00 series
pumps. Line the meter bracket up for installation and
insert the bolts in the two holes that align with the
corresponding holes on the pump outlet. Once the meter
bracket is bolted securely in place install the two plugs in
the holes that were not used to prevent moisture from
entering
them.
Calibration
The Fill-Rite Series 900 meters can be calibrated for either U.S. gallons or liters. Calibration is
required upon installation,
after disassembly,
different
viscosity fluid. Depending
either U.S. gallons or liters using mineral spirit. Calibration must be done between 6 and 40
GPM (23 and 151 LPM)_ Meter calibration can be easily changed by following the
calibration procedure. A container of KNOWN volume will be needed for the calibration
procedure. For the 900 Series meter, a five gallon container or larger should be used.
Procedure
for
Calibration:
I)
For the most accurate calibration, install the meter in the application. Fill a container to a
known volume with the liquid to be measured
2)
If meter amount is incorrect, turn calibration screw (item 31) counterclockwise for less
liquid, or clockwise for more liquid.
3)
Repeat steps 1 and 2 until calibration is acceptable.
Operating
Instructions
For accurate measurement and to prevent meter damage, meter and piping must always be
filled with liquid and free of air Meter should be calibrated per instructions in this manual
prior to its use,
I)
Stop flow of liquid.
2)
Reset register to
3)
Meter is ready for use. Start flow of liquid. Do not exceed 50 PSI of line pressure.
Maintenance
Your Fill-Rite 900 series meter should operate virtually maintenance
Liquids, however, can dry out while in the meter housing, causing the meter to stop or perform
poorly. If this happens, meter should be thoroughly cleaned
Cleaning
Instructions
Run a flushing fluid through the meter. For a more thorough cleaning, disassemble the meter
per "ASSEMBLY
/ DISASSEMBLY"
all meter components
thoroughly.
IMPORTANT!
When retuming
accompanied by a note stating what chemicals have been pumped through it.
Meters not adhering to these specifications may be refused for service.
This
after significant
wear or when metering
on the model, Series 900 meters are factory calibrated
section, "Meter Chamber Assembly/'
Recalibrate
meter following calibration
a meter for service, it must be triple rinsed and
4
a
in
free.
Certain
subsection.
Rinse
instructions
above.
loading