Mounting and
operating instructions
Procedure/Trouble-shooting – Direction connection
Establishing an operational Ethernet connection between FA 45 Vision Sensor and Vision Viewer CE
Important:
To configure the PC via Direct Connection it is neccessary to change it´s IP- configuration.
Please contact your system administrator to inform about changes !
Sensor correctly connected?
- Power supply 24V DC
- Networkcable (crossed) Nr. 902-51736
yes
Electrical connection OK?
- green Pwr LED at FA 45 active?
- Status LED at networkadapter active?
- and/or LAN Status shows "Connection
established". (Control panel
connections
LAN-Connection
yes
IP address of PC fits to IP of Sensor?
Sensor IP: 192.168.100.100/24 (default)
- PC: e.g. 192.168.100.101/24
( /24 means, 24Bit Subnetmask =
255.255.255.0)
yes
SensoFinder finds Sensor?
- start SensoFinder
- press button "Find"
- mark Sensor
- Button "Connect" is aktive?
yes
SensoFinder starts applicaiton- software?
- Double click on sensor in the list
- PC / application- software starts
yes
Now the parameter setting of the sensor /
application can be done
Vision Viewer CE FA 45 GB - 068-14298 - 23.03.2010-00
yes
no
Network-
Status)
yes
no
Configuration: Start
LAN-Connection
yes
Please contact your system administrator as this can cause
Start
no
If four positive answers are displayed, go on with "Yes"- path
After parameter setting is finished, reactivate firewall again!
yes
no
Sensorversion is displayed in the SensoFinder (e.g. 40). Table of
compatibility and corresponding software at www.sensopart.com
Connect Sensor correctly!
- Power supply 24V DC
- Networkcable (crossed) Nr. 902-51736
no
Control / correct settings
- IP of PC (fix, to the sensor corresponing IP):
e.g. 192.168.100.101; - Subnetmask: 255.255.255.0
Control panel
Properties
"Repair" Networkconnection
problems!
Control panel
Networkconnections
on used "LAN connection"
(delets ARP Cache, amongst others).
IP-Connection test
- in Command
Line:
(IP address of the sensor) [ENTER] .
(Command input:
Start
All Programs
Accessories
Deacticate / adapt firewall
Please contact your sytem administrator
IP-Connection test (see above)
Caution!
Sensor- and Softwareversion test
Networkconnections
Internetprotocol (TCP/IP)
Right mouse click
Repair
ping 192.168.100.100
Command Line)
no
yes
no
Fig. 8
155-00509
23