3. Short press the [-] or [+] button to adjust the set temperature.
4. after 30 seconds, the new settings are automatically saved and the device returns to the selected mode.
5.3. SWITCH ON/OFF WINDOW CONTACT
1. remember the original setting of the rotary switch
2. turn the rotary switch to setting '0'
3. the 3 LEds (red, green and blue) on the JdPC are blinking
4. hold the '-' button down until the blue or the red LEd lights up
5. the setting of the window contact changed
– blue LEd: window contact inactive
– red LEd: window contact active
6. repeat these steps until the desired result is obtained.
7. turn the rotary switch back to its original setting
5.4. FACTORY RESET
1. disable power charge.
2. Press and hold down both the [-] and [+] button on the circuit
board and switch on the power again. the blue LEd will light up,
followed by the green LEd 2 seconds later and the red LEd 4 se-
conds later. release the buttons as soon as all 3 LEds are flashing
3. the controller will return to the Factory default settings, all LEds
will flash for 8 seconds..