Siemens SIFLOW FC070 Instructions De Service page 133

Table des Matières

Publicité

Code
Evénement
86
HE_FLOW_DATA_DIG_IN_FUNCTION
87
HE_FLOW_DATA_SENSOR_SIZE
88
HE_FLOW_DATA_CALIBRATION_FACTOR DR9: calibration_factor hors plage
89
HE_FLOW_DATA_CORRECTION_FACTOR DR9: correction_factor hors plage
90
HE_FLOW_DATA_SENSOR_TC
91
HE_FLOW_DATA_DENSITY_PARM_A
92
HE_FLOW_DATA_DENSITY_PARM_B
93
HE_FLOW_DATA_DENSITY_TC
94
HE_FLOW_DATA_DENSITY_OFFSET
95
HE_FLOW_DATA_DENSITY_FACTOR
96
HE_FLOW_DATA_FRACTION_OFFSET
97
HE_FLOW_DATA_FRACTION_FACTOR
98
HE_FLOW_DATA_SIM_VAL_MASSFLOW
99
HE_FLOW_DATA_SIM_VAL_VOLUMEFLO
W
100
HE_FLOW_DATA_SIM_VAL_DENSITY
101
HE_FLOW_DATA_SIM_VAL_SENSOR_TE
MP
102
HE_FLOW_DATA_SIM_VAL_PERCENT_FR
ACTION_A
103
HE_FLOW_DATA_SIM_VAL_OUTPUT_1
104
HE_FLOW_DATA_SIM_VAL_OUTPUT_1_F
REQ
105
HE_FLOW_DATA_SIM_VAL_OUTPUT_2
106
HE_FLOW_DATA_SIM_VAL_OUTPUT_2_F
REQ
107
HE_FLOW_DATA_SIM_VAL_INPUT
108
HE_FLOW_DATA_SIM_VAL_ERROR_NO
109
HE_FLOW_DATA_BATCH_QUANTITY
110
HE_FLOW_DATA_BATCH_COMPENSATIO
N
111
HE_FLOW_DATA_BATCH_LEAD_CONSTA
NT
112
HE_FLOW_DATA_BATCH_TWO_STAGE_L
EVEL
113
HE_FLOW_DATA_TOTALIZER_1_PRESET
_VAL
114
HE_FLOW_DATA_TOTALIZER_2_PRESET
_VAL
115
HE_FLOW_DATA_ZERO_OFFSET_PRESE
T_VAL
116
HE_FLOW_DATA_LIMIT_1_SELECTION
117
HE_FLOW_DATA_LIMIT_1_DIRECTION
SIFLOW FC070 avec SIMATIC S7
Instructions de service, 06/2009, SFIDK.PS.028.T1.04
Alarme, messages d'erreurs et messages système
11.7 Messages d'erreurs du SIFLOW FC070
Description, explication succincte
Fonction de l'entrée TOR paramétrée en dehors
de la plage admissible DR6 :
digital_input_function hors plage
DR9 : sensor_size hors plage
DR9 : sensor_TC hors plage
DR9 : density_parm_A hors plage
DR9 : density_parm_B hors plage
DR9 : density_TC hors plage
DR9 : density_offset hors plage
DR9 : density_factor hors plage
DR9 : fraction_factor hors plage
DR9 : fraction_offset hors plage
DR10: simulation_value_massflow hors plage
DR10 : simulation_value_volumeflow hors plage
DR10 : simulation_value_density hors plage
DR10 : simulation_value_sensor_temperature
hors plage
DR10 : simulation_value_percent_fraction_a hors
plage
DR10 : simulation_value_output_1 hors plage
DR10 : simulation_value_output_1_frequency
hors plage
DR10 : simulation_value_output_2 hors plage
DR10 : simulation_value_output_2_frequency
hors plage
DR10 : simulation_value_input hors plage
DR10 : simulation_value_error_no hors plage
DR11 : batch_compensation hors plage
DR11 : batch_quantity hors plage
DR11 : batch_lead_constant hors plage
DR11 : batch_two_stage_level hors plage
DR11 : totalizer_1_preset_value hors plage
DR11 : totalizer_2_preset_value hors plage
DR11 : zero_offset_preset_value hors plage
DR12 : limit1_selection hors plage
DR12 : limit1_direction hors plage
ID événement
S7 (HEX)
F9601156
F9601157
F9601158
F9601159
F960115A
F960115B
F960115C
F960115D
F960115E
F960115F
F9601160
F9601161
F9601162
F9601163
F9601164
F9601165
F9601166
F9601167
F9601168
F9601169
F960116A
F960116B
F960116C
F960116D
F960116E
F960116F
F9601170
F9601171
F9601172
F9601173
F9601174
F9601175
131

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Simatic s7