FUXTEC FX-RM Serie Mode D'emploi page 72

Masquer les pouces Voir aussi pour FX-RM Serie:
Table des Matières
Manual_FX-RM_Series_Int24_rev24
Maintenance schedule
Regular
Before
maintenance
each use
Engine oil
Check
Change
Air filter
Check
Change
Spark plug
Check
Change
Fuel tank
Check
and filter
Change
Valve
Check
clearance
Change
Combustion
chamber
clean
Troubleshooting
The engine does not
start
1. Check fuel level
2. Remove and check
the spark plug
3. User errors
4. Impurities
5. Electrical contact
Item
Spark plug gauge
Valve clearance (cold)
72
First
Every 3
month or 5
months or
operating
25
hours
operating
hours
*
*
*
After 200
operating
hours
Possible causes
No more fuel in the tank
Impure gasoline: Engine stored
without care, proper emptying of
the tank or filled with contaminated
gasoline
Spark plug defective, dirty, or
incorrectly attached
Spark plug flooded with gasoline
forgotten to operate the brake lever
at start
Fuel filter or carburetor
contaminated
When tightening the engine brake
lever, the contact plate at the end of
the Bowden cable does not close
Specification
0,6mm
INSIDE: 0,06mm +/- 0,02mm
OUTSIDE: 0,08mm +/-
0,02mm
Every 6 months
Once a
or 50 operating
year or
hours
100
operating
hours
*
*
*
Troubleshooting
Refill
Empty the tank and the carburetor.
Fill up with new fuel (super unleaded)
Replace the spark plug
Dry and reinstall properly
While the starter is pulled, the upper
lever must be pulled to the handle
Replace or clean the components
Bend back the holder to create the
electrical contact
Maintenance
Check page 69
Please contact FUXTEC
customer service
Every 2
years or
250
operating
hours
*
Table des Matières