Programmable Function Settings - SCS Sentinel INTENSIVE 3A Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

D

3.4 PROGRAMMABLE FUNCTION SETTINGS

LED Display
Definition
F1
Options of Gate
Opening direction
F2
Automatic Closing
The reactions of the
photocells/ safety
F3
edge/ loop detector
when they detecting
obstacles
F4
Motor Speed
F5
Motor Over Current
Setting
F6
Pedestrian Mode
F7
Pre-flashing
Deceleration point
F8
programming of total
travel distance
Deceleration Speed
F9
Auto - Reverse when
FA
object impacted
Function
Value
F1-0
Clockwise Opening
F1-1
Counterclockwise Opening
F2-0
No automatic closing
F2-1
5 seconds
F2-2
15 seconds
F2-3
30 seconds
F2-4
45 seconds
F2-5
60 seconds
F2-6
80 seconds
F2-7
120 seconds
F2-8
180 seconds
F3-1
Please refer to page 9,
F3-2
F3 settings
F3-3
F4-1
Slow
F4-2
Medium
F4-3
Fast
F4-4
Very Fast
Light
F5-1
Light
F5-2
Light
F5-3
F5-4
Light
F5-5
Light
F5-6
Light
F5-7
Light
F5-8
Light
F5-9
Light
3 seconds
F6-0
6 seconds
F6-1
9 seconds
F6-2
12 seconds
F6-3
15 seconds
F6-4
18 seconds
F6-5
The flashing light blinks
F7-0
when the gate starts to move.
The flashing light blinks 3
F7-1
seconds before the gate
starts to move.
75%
F8-1
80%
F8-2
F8-3
85%
F8-4
90%
F9-1
50% full speed
F9-2
25% full speed
F9-3
10% full speed
FA-0
No Auto - reverse
FA-1
1 second
FA-2
3 seconds
Reverse to the end
FA-3
Description
1. The function can adjust the dir
ection of gate opening.
2. The factory setting is "F1-1".
1. This function can cause the gate
to close automatically after the
paused time.
2. The factory setting is "F2-3":
30secs as the pause time.
1. The factory setting is "F3-1".
1. The function can adjust the
running speed of motor.
2. The factory setting is "F4-4".
Heavy
1. The function can adjust the
Heavy
running force of motor to be
compatible with the gate weight.
Heavy
2. The factory setting is "F5-4".
Heavy
3. The motor force value:
F5-1: 2A
F5-6: 7A
Heavy
F5-2: 3A
F5-7: 8A
Heavy
F5-3: 4A
F5-8: 10A
F5-4: 5A
F5-9: 13A
Heavy
F5-5: 6A
Heavy
4. As over current setting
Heavy
1. The function can adjust the time
of opening partially.
2. The factory setting is "F6-1".
3. Press button B on the remote to
operate the pedestrian mode.
1. The factory setting is "F7-0".
1. The factory setting is "F8-1".
1. The factory setting is "F9-1".
1. The factory setting is "FA-3".
8

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Intensive 3b

Table des Matières