Télécharger Imprimer la page

Dustcontrol DC 5800 H Turbo EX Manuel D'utilisation page 34

Masquer les pouces Voir aussi pour DC 5800 H Turbo EX:

Publicité

The container under the cyclone should be emptied when it is filled to a maximum of 2/3.
IMPORTANT
The barrel must be earthed during emptying and changing the bag. See the chapter Grounding.
Be careful when releasing the fasteners – they can open with great force – especially when the material is heavy.
Be aware that emptying the container may pose a risk of explosion, i.e. that an explosive atmosphere may occur
and that static charge may be generated by the friction of the particles against the container. For appropriate
measures, see IEC/TS 60079-32-1.
When the container is to be emptied, the two fasteners must be carefully released, one at a time, to prevent dust
from swirling up unnecessarily. When the machine's container has been lowered, turn on the separator again so
that any stuck particles are sucked into the filter cyclone.
Carefully remove the filled sack from the edge of the container and immediately seal it tightly.
Fit a new plastic sack and place the opening carefully back over the edge of the container. Make sure that no
creases are formed and that the sack is not damaged. Then carefully install the tray under the separator and fasten
the two hooks, turn off the machine and once more secure the tray on the machine, make sure that the fastening
hooks are located properly and check for leakage.
Filter cleaning:
The machine's filter needs to be cleaned when the manometer's arrow is in the red field.
1.
Leave the machine on and close the damper on the cyclone inlet. Reset the filter cleaning button.
2.
Wait 6-10 pulses.
3.
Switch off the machine.
4.
Open the damper on the cyclone inlet and reset the filter cleaning button.
5.
Turn on the machine.
6.
Check that the pressure gauge is on green. If not - repeat the procedure. If the meter reads red, the fine filter
needs to be replaced. If, despite changing the filter, it is still red, the vacuum valve needs to be checked.