Type and order code
1
Design
Heat source
1.1
model
1.2
Contr.
1.3
Thermal energy metering
1.4
Installation location
1.5
Performance levels
2
Operating limits
2.1
Heating water flow
2.2
Cold water (heat source)
3
Flow / sound
3.1
Heating water flow at internal pressure differential
Nominal flow according to EN14511 at W10-7 / W35-30
Minimum heating water flow
3.2
Cold water flow at internal pressure differential
Nominal flow according to EN14511 at W10-7 / W35-30
Minimum cold water flow
3.3
Sound power level according to EN 12102
3.4
Sound pressure level at a distance of 1 m
4
Dimensions, connections and weight
3
4.1
Device dimensions
4.2
Weight of the transportable unit(s) incl. Packaging/full
4.3
Device connections for heating system
4.4
Device connections for heat source
4.5
Refrigeran / total filling weight
4.6
Lubricant / total filling quantity
4.7
Volume of heating water in device
4.8
Volume of heat transfer medium in device
5
Electrical connection
5.1
Supply voltage / fuse protection Compressor
5.2
Control voltage / fuse protection
5.3
Degree of protection according to EN 60 529
5.4
Starting current with soft starter
5.5
Nominal power consumption W10/W35/max. consumption
5.6
Nominal current W10/W35/cos
5.7
Power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device is protected against freezing
7.2
Max. operating overpressure (heat source/heat sink)
5
8
Heat output / COP
Heat output / COP
1. The specified sound levels apply if the supporting feet (available as an option) are not used. If the supporting feet are used, the level can deviate by up to 3dB(A).
2. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
3. Please note that additional space is required for pipe connections, operation and maintenance.
4. Flat-sealing
5. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation
can be found in the respective sections of the installation and operating instructions. The specified values, e.g. W10 / W35, have the following meaning: Heat source temperature
10 °C and heating water flow temperature 35 °C.
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
°C
°C
m³/h / Pa
at W10-7 / W45-40
m³/h / Pa
at W10-7 / W55-47
m³/h / Pa
m³/h / Pa
m³/h / Pa
at W10-7 / W45-40
m³/h / Pa
at W10-7 / W55-47
m³/h / Pa
m³/h / Pa
1
dB(A)
2 1
dB(A)
H x W x D mm
kg
4
Inches
4
Inches
type/kg
type/litres
Litres
Litres
Primary circulating pump
Joint supply
Compressor and primary circulating pump
A
5
kW
A / --
W
7
bar
Performance level
at W10 / W55
kW / ---
at W10 / W45
kW / ---
at W10 / W35
kW / ---
452235.66.09 · FD 9506
WI 18TU
Water
Universal
WPM EconPlus
Integrated
Indoors
1
20 to 62 ± 2
+7 to +25
2,9 / 16200
2,7 / 14100
1,6 / 5100
1,6 / 5100
4,0 / 15200
3,4 / 11200
3,3 / 10500
3,3 / 10500
44
32
845  650 x 665
160
Thread 1¼" external
Thread 1¼" external
R410A/3,4
Polyolester (POE)/1.2
4,5
2,9
3~/PE 400 V (50 Hz) / C13 A
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C13 A
1~/N/PE 230 V (50 Hz) / C13 A
1~/N/PE 230 V (50 Hz) / C13 A
IP 21
23
2,95 / 5,4
5,32 / 0,8
thermostatically controlled
6
Yes
3,0
EN 14511
1
2
15,1 / 3,6
15,6 / 4,4
17,1 / 5,8
WI 10TU - WI 22TU
WI 22TU
Water
Universal
WPM EconPlus
Integrated
Indoors
1
20 to 62 ± 2
+7 to +25
3,8 / 22900
3,6 / 20700
2,2 / 7700
2,2 / 7700
5,3 / 21400
4,7 / 17100
4,0 / 12100
4,0 / 12100
47
35
845  650 x 665
179
Thread 1¼" external
Thread 1½" external
R410A / 4,0
Polyolester (POE) / 1,9
5,6
3,3
3~/PE 400 V (50 Hz) / C16 A
3~/PE 400 V (50 Hz) / C10 A
3~/PE 400 V (50 Hz) / C16 A
IP 21
28
3,91/ 7,2
7,06 / 0,8
thermostatically controlled
6
Yes
3,0
EN 14511
1
2
20,0 / 3,6
21,1/ 4,4
22,3 / 5,7
EN-11