15 liter, the descaling function will start and the machine will automatically enter
the descaling program.
2. In standby mode, keep pressing the buttons of "
" and "
", the machine will
start the descaling process. When the indicator of Power button turns on and the
descaling indicator flashes quickly, follow the steps as below.
Step 1: Start the descaling cycle
Turn the knob to "
" position.
The descaling indicator turns to flash slowly, the pump starts to work, the hot water
dispenses from the brewing head and steam tube, and the pump will make
different noises after 2 minutes. When the hot water stops coming out from
brewing head and steam tube, turn the knob to "
" position.
The indicator of "
" button lights solidly while the steam indicator flashes.
Please perform the step 2.
Step 2: Prepare to clean up
Important: A maximum of 5 minutes is allowed to take to complete the following
steps before exiting from the descaling cycle.
The steam tube and brewing head need to be cleaned with fresh water for
removing the descaling solution.
Clean the water tank
Fill the water tank with water
Empty the containers
Step 3: Start cleanup
Turn the knob to the " " position,
At that time, the indicator of "
" and the descaling indicator flash.
The pump starts to work, the hot water will dispense from the brewing head and
steam tube, and the pump will make different noises after 2 minutes.
When hot water stops coming out from brewing head and steam tube, the
descaling is complete.
Descaling cycle completed
The indicator stops illuminating and knob indicator "
" starts flashing, which
- 22 -