Emglo K15A-8P Guide D'utilisation page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CODE
POSSIBLE CAUSE
16
Loose pulley
17
Loose flywheel
18
Carbon build-up in pump
19
Belt to tight
20
Pulley misalignment
21
Extension cord is wrong length or gauge
22
Loose electrical connections
23
Pump oil is low
24
Regulator is not adjusted correctly for accessory being
used
25
Damaged regulator
26
Detergent type oil being used in pump
POSSIBLE SOLUTION
Tighten pulley set screw, torque to 145–165 in.-lbs.
(16.4– 19.6 Nm).
Tighten
flywheel
screw,
(20.3– 24.4 Nm).
Contact an EMGLO factory service center or an EMGLO
authorized service center.
Check belt tension, see Adjusting Belt Tension under
Maintenance.
See
Motor
Pulley/Flywheel
Maintenance.
Check for proper gauge wire and cord length. See
Extension Cords under Installation.
Contact an EMGLO factory service center or an EMGLO
authorized service center.
Add EMGLO Synthetic Blue compressor oil to pump. See
Compressor Pump Oil under Maintenance.
It is normal for some pressure drop to occur when an acces-
sory is used, adjust the regulator as instructed in Regulator
under Features if pressure drop is excessive.
NOTE: Adjust the regulated pressure under flow conditions
while accessory is being used.
Replace.
Drain oil and refill pump with EMGLO Synthetic Blue
compressor oil.
22
torque
to
15–18
ft.-lbs.