Air leaks from safety valve ......................................................................................................... 6
Compressor is not supplying enough air to operate accessories.............................................. 2,7,8,9,10,12,13
Restricted air intake. .................................................................................................................. 12
Excessive vibration .................................................................................................................... 14
Knocking noise .......................................................................................................................... 3,6,13,14,16,17,18,19
Excessive belt wear ................................................................................................................... 13,14,16,19,20
Squealing sound ........................................................................................................................ 13,23
Motor will not run ....................................................................................................................... 15,21,22,32,34,35,36
Pressure reading on the regulated pressure gauge drops when an accessory is used ........... 24
Regulator knob has continuous air leak .................................................................................... 25
Regulator will not shut off air outlet ........................................................................................... 25
Moisture in pump crankcase ...................................................................................................... 2,5,11,26,27,28,29,30,31
Pump will not run ....................................................................................................................... 32
Air tank pressure will not build ................................................................................................... 32,33
CODE
POSSIBLE CAUSE
1
Unloader valve does not release pressure when air tank
reaches blow-off pressure
2
Fittings are not tight
3
Defective unloader valve

Troubleshooting Codes

POSSIBLE SOLUTION
Unloader valve must be replaced. Contact an EMGLO fac-
tory service center or an EMGLO authorized service center.
Tighten fittings where air can be heard escaping. Check fit-
tings with soapy water solution. DO NOT OVERTIGHTEN.
Turn off motor, rotate manual lock unloader lever to the closed
perpendicular position. If air leaks out of air tank through
unloader valve, replace unloader valve.