Elixo Optimo 24V RTS
3 - USE AND OPERATION
3.1
Gate fully open
Press the programmed button to open the gate fully.
Gate pedestrian opening
Press the programmed button to open the gate in pedestrian mode.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
STOP
STOP
STOP
3.2
Gate fully open
Gate pedestrian opening
3.3 Obstacle detection operation
When an obstacle is detected during opening, the gate will stop. Pressing the
programmed button on the remote control closes the gate.
If an obstacle is detected during closing, the gate will stop and reopen.
3.4 Automatic closing operation
If the automatic closing mode has been programmed during installation, the
gate will operate as follows.
Pressing a programmed button on the remote control will cause the gate to
open. The gate will close automatically after 30 seconds. If photoelectric cells
are installed, any movement in front of the cells will cause the gate to close
automatically after 5 seconds.
The gate can be held in the opened position by giving a stop command during
the time delay. To close the gate, press the remote control button again.
STOP
STOP
30 s
30 s
STOP
3