9 Solving malfunctions and problems

- When working on the equipment, the equipment must be voltage-free;
- The electrical installation must be carried out by an electrical engineer with the relevant
training and qualifications
Signaling
Problem
LED not lit
No power supply
LED continually
Bad discharge
green
No discharge
LED blinks slowly
No or insufficient
or intermittently
compressed air from
green during use
the gun
LED blinks red
Moisture in the airway High voltage parts wet due to the
Defective gun
Table 3: malfunctions

10 Repairs

The Cleanflex can only be repaired by Simco Ion.
In case of problems and / or questions, please contact Simco Ion or a Simco Ion representative
in your region.
A malfunctioning or defective Cleanflex can be returned to Simco Ion for repairs by following the
following RMA (Return Merchandise Authorization) procedure:
1.
Fill in the Simco Ion RMA form
By entering the article number and serial number you can determine whether your
product will be repaired under warranty or if there are costs involved.
2.
Return sending:
a. Pack the defective Cleanflex properly;
b. Display the RMA number;
c. Send the package to the stated return address of Simco Ion.
CleanflexEasy_UM_9752050810_NL_D_GB_F_V1_2
What this means
Power supply defective
Power supply not connected
Power supply incorrectly
connected
Compressed air pressure set too
low
Ionization component in the head
worn out
Ionization component in the head
defective or worn out
Compressed air not connected
Compressed air pressure set too
low
Defective valve
use of moist compressed air
Internal defect
www.simco-ion.co.uk/repair
What to do about this
Restore power supply
See H5
Increase the pressure
See H6
Repair the gun
See H10
Repair the gun
See H10
Connect compressed air
See H5
Increase compressed air
pressure
See H6
Repair the gun
See H10
Use dry clean compressed air
and blow through without
supply voltage
Repair the gun
See H10