Chimney Pot; Installation; Requirements For The Installation Premises - Ravelli Calliope EU Manuel D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Rev.0 05/05/20
Page 56
there must be a maximum of 2 changes in direction and angles must not exceed 45°;
the chimney inside the home, however, must be insulated and can be inserted into a skylight shaft, as long as it respects
standards regarding placing inside a tube;
the smoke conduit must be connected to the chimney using a "T" fitting with an inspection collection chamber for combustion
residue and especially for collecting condensation.
��
It is necessary to check the safety distances that need to be observed when there are flammable materials and the type of
insulating material that needs to be used is on the chimney data plate.
Use watertight pipes with silicone seals.
It is forbidden to use the discharge mounted directly on the wall or directed towards indoor spaces and any other type of
discharge that is not set forth by the regulation in force in the country of installation (Note: in Italy only roof-discharge is
allowed).

Chimney pot

The chimney pot, i.e. the top end of the chimney, must fulfil the following characteristics:
the cross-section of the smoke outlet must be at least twice the internal cross-section of the chimney;
it must stop water or snow from getting in;
make sure the smoke is taken away even when there is wind (wind resistant chimney pot);
the outlet height must be outside of the reflux zone (refer to national and local regulations to calculate the reflux zone);
it must always be built at a distance from antennas or dishes, it must never be used as support.

Installation

For appliance installation and use it is necessary to observe all of the local, national and European laws and regulations.
Stove installation and the preparation of the building work must observe the regulation in force in the country of installation
(ITALY = UNI 10683).
��
The installation activities must be carried out by a technician that is qualified and/or authorised by the Manufacturer. The staff
in charge of installation must issue a declaration of conformity of the system to the buyer, whereby they take full responsibility
for the final installation and good operation of the installed product. Ravelli shall not be held liable if these precautions are
not followed.

Requirements for the installation premises

The stove installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake
connected to the outdoors.
��
The installation room must have an air intake with a free cross-section of at least 100 cm
��
For installation in the presence of other combustion appliances or VMC system it is necessary to check the appliance
for correct operation.
The stove must be placed inside living quarters. It must never be installed outdoors. The volume of the room where it is installed
must be suitable for the power of the appliance and, in any case, greater than 15 m
ATTENTION! When extraction fans (example: extraction hoods) are used in the same room or space as the stove, this can
cause problems to stove operation.
The stove must be installed on a floor with suitable load capacity. If the existing position does not fulfil this requirement, it is
necessary to take due measures (for example, using a load distribution plate).
ATTENTION! provide due insulation if the surface is made of flammable material.
If the side walls adjacent to the stove are made of a flammable material, it will be necessary to position the stove at least 30 cm from
them.
Use and maintenance manual Calliope EU
.
2
.
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Calliope stone euCalliope view euMinerva euMinerva stone eu

Table des Matières