Digital Inverter
Indoor/outdoor
connecting wire
Earth screw
1
2
3
Cord clamp
Cord clamp
WARNING
Be sure to attach the provided clamp filter to the power
supply wire in order to conform to EMC standards.
8
EARTHING
WARNING
•
Be sure to connect the earth wire. (grounding work)
Incomplete grounding may cause an electric shock.
Connect the earth line properly following applicable technical standards.
Connecting the earth line is essential to preventing electric shock and to reducing noise and electrical charges on the outdoor
unit surface due to the high-frequency wave generated by the frequency converter (inverter) in the outdoor unit.
If you touch the charged outdoor unit without an earth line, you may experience an electric shock.
EN
All manuals and user guides at all-guides.com
Power supply wire
Earth screw
L1
L2
L3
N
Cord clamp
Clamp filter
(accessory)
Cord clamp
Stripping length power cord and connecting wire
10
1
2 3
10
50
(mm)
Earth line
Connecting wire
19
10
L1 L2 L3 N
50
30
Earth line
Power supply wire
10
40