Télécharger Imprimer la page

Valor Retrofire RF24JB Manuel D'installation Et D'utilisation page 2

Les langues disponibles

Les langues disponibles

Conversion Procedure
1. If the fi replace is already installed, remove window
cover with barrier screen, window, and fuel bed.
2. Disconnect the gas inlet pipe from the inlet elbow
fi tting on the valve.
3. Remove the rear log support (4 screws).
4. Remove the burner module (4 screws).
5. Disconnect the burner
elbow injector from the
pipe, using a 11/16" (17
mm) wrench.
6. Remove the 6 screws
(2 underside of bracket)
securing the burner
brackets to the burner
tray.
Burner
fixing nuts
Fixing screws
underside of
brackets
2
Fixing
screws
7. Detach the two burner support brackets from the
burner by removing two nuts, using a 5/16" (8 mm)
wrench.
8. Replace the main burner with the burner assembly
supplied with the conversion kit and reassemble
the module.
9. Accessing the pilot assembly
from the underside of the
module, disconnect the pilot
pipe, using a 7/16" (11 mm)
wrench.
10. Remove the pilot injector.
Replace with the appropriate
gas injector.
11. Remove and replace the minimum rate by-pass
screw from the valve with the appropriately labelled
by-pass screw—see Specifi cations table on page
1. The screw has a rubber o-ring holding it into the
valve body and may require prying out or removing
the screw with needle nose pliers.
Note - The pilot
injector should be
slipped onto the
end of the pipe
from the side. The
pilot pipe, with
injector attached,
should be inserted
into the assembly.
RF24BV or RF24XB
loading

Ce manuel est également adapté pour:

Retrofire ra24jbnkRetrofire ra24jbpk