Thank you for purchasing one of our products. We recommend you carefully read this instruction manual: it contains
important information regarding safety regulations for use and maintenance of the appliance. It is also recommended to
keep this document carefully to consult in case of necessity.
1. Read these instructions carefully in order to familiarize yourself with the appliance before connecting it to its gas
container.
2. Keep these instructions for future reference.
3. Carefully read the information stamped on the cartridge before you connect the unit to it.
4. ART 1065E: This device works only with direct pressure gas cartridge KEMPER 581 and 581N.
5. It can be dangerous to try to use other gas cartridges.
6. Make sure the valve is closed before handling the equipment.
7. Always check that the seal, between the device and the cartridge, is in place and in good condition before
connecting it to the gas container.
8. Never use appliances with worn or damaged seals.
9. Do not use appliances which is leaking, damaged or which does not operate properly.
10. This device should only be used in sufficiently ventilated area in accordance with national requirement. The volume
of air needed for proper combustion and prevent formation of dangerous unburned gas mixtures is 2 m
11. The appliance should be operated away from flammable materials and at a distance of 70 cm from furniture, walls
and ceiling.
12. If there is a leak on Your appliance (smell of gas) take it outside immediately into a well-ventilated flam free location,
where the leak may be detected and stopped. If you need to check for leaks on your appliance, do it outside. Do
not try to detect leaks using flames, use our item Revelgas 1726 or soapy water.
13. Do not modify the device: it can be dangerous and void the warranty and all liability.
14. Do not use the appliance if not complete all of its components.
15. Do not use an appliance which is leaking damaged or which does not operate properly.
GENERAL INSTRUCTIONS FOR USE AND ASSEMBLY
1. Check that the gas knob (D) is completely closed.
2. Check the presence and good condition of the seal inside the valve's threaded area and screw the appliance
completely on the cartridge.
3. Slightly open the knob (D) counter clockwise and regulate ignition button (D) on ON and push the ignition button
(E). Repeat in case of lighting failure.
POWER ADJUSTMENT
1. Increase the power of the apparatus by turning the gas knob (D) to the sign «+» (counter clockwise). To decrease
the power, turn the knob (D) to the sign «-» (clockwise) until the shutdown.
2. After ignition, in order to keep continuous flame, press flame lock button (F). Pressing ignition button (D) it unlocks
the flame block button (F) and the flame blow out automatically.
3. After working turn ignition button (G) to OFF and to avoid accidental ignition.
CARTRIDGE REPLACEMENT
1. The cartridge must be replaced in a ventilated area, preferably outside, away from open flames, pilot flames and
away from other people.
2. Make sure the valve is closed, unscrew the unit from the empty cartridge, check the presence and condition of the
seal between the device and the cartridge, screw the unit on the new cartridge.
3. Never throw an empty cartridge into the fire.
MAINTENANCE
1. To clean the body of your device, use a cotton ball soaked in warm water and soap. Never use abrasive products.
2. To clean the burner, use a soft brush.
STORAGE
When not using the equipment must be stored upright, in suitable places, to protect it from degradation risks, the place
must be well ventilated and away from children.
MAINTENANCE – REPAIR
For any support on this product, kindly contact our customer assistance departments in Parma (Italy) – Via Prampolini,
1/Q, 43044 Lemignano di Collecchio – Tel. +39 0521/957111 – Fax +39 0521/957195 - www.kempergroup.it -
info@kempergroup.it
Merci d'avoir acheté un de nos produits, nous espérons de pleinement vous satisfaire. On vous conseille de lire
attentivement ce manuel d'instruction, car il contient des informations importantes concernant les normes de sécurité
pour l'utilisation et la maintenance de cet appareil. On vous conseille de garder ce document avec soin et le consulter
en cas de nécessité.
1. Lire attentivement cette notice d'utilisation pour vous familiariser avec l'appareil avant de le connecter à une
cartouche/bouteille de gaz.
2. Conserver cette notice pour utilisation ultérieure.
3. Lire attentivement la notice imprimée sur la cartouche de gaz avant de la connecter à l'appareil.
4. ART 1065E : Cette appareil fonctionne exclusivement avec la cartouche de gaz a pression directe KEMPER 581
e 581N.
Il peut être dangereux d'utiliser d'autres cartouches de gaz.
5.
6. Assurez-vous que le robinet soit fermé avant de manipuler l'appareil.
7. Contrôler toujours la présence et le bon état du joint entre l'appareil et la cartouche avant de les assembler.
DT Istr (1065E) 03/2019 – REV 3_10/2023
GENERAL WARNING / IMPORTANT
AVERTISSEMENTS / IMPORTANT
1065E
3
/h per kW.
6/12