6 SPECIAL FEATURES

6.1 Power failure:
When tension is restored after a power failure during Preparing, Wait or Shutdown, the card returns to the previous programme.
When tension is restored following a power failure with a cycle in progress, the card shuts down the machine (power failure), indicates
that the cycle has been interrupted and waits for the reset procedure to be carried out.
6.2 Reset procedure:
In the event of a Shutdown or when the stop switch is pressed with a cycle in progress, the door remains locked. To open the
door the door release sequence must be carried out from the keyboard as follows:
4.
Press the STOP and START switches together and keep pressed for 3".
5.
Press the short programme switch (P01) followed by the standard program key (P02)
6.
The machine is reset and returns to standby.
N.B. : If the machine shutdown persists due to a fault in one of its components (e.g.: faulty probe, unsuitable levels, etc.), the door
is released and the machine remains inactive.
Seek technical assistance.

7. DIAGNOSTICS

⇒7.1 No detergent:
A dedicated digital input detects the lack of detergent.
The cycle in progress continues without interruption, the lack of detergent is indicated on the led.
⇒7.2 Heating elements failure:
If the heating elemet remain active for longer than the set time (P20) the cycle is interrupted and the machine shuts down on the
presumption that there is a fault in the heating element.
⇒7.3 Door locked warning:
This warning message is given if the door is open and locked.
⇒7.4 Time-out for cold water loading:
Diagnosed after setting time for the cold water solenoid valve to remain open or when the required water level is not reached within
the setting time.
⇒7.5 Time-out for water discharge:
Diagnosed if the set time for the discharge pump to remain active (P19) has elapsed and the tank is still at an active level.
⇒7.6 Door not locked:
If when the door lock is activated the corresponding digital input of the electronic card is not activated within the set time (P15), the
machine shuts down and the display indicates that the door is not locked.
⇒7.7 Temperature probe fault:
The machine shuts down and indicates tank probe failure or boiler probe failure..
29
DAQF028_rev0.10