Figure 10 Adhesive application
Please note that, as soon as the two components are mixed, the adhesive cures within a few minutes.
INFORMATION:
Once the adhesive in the mixing tube has cured, it cannot be used again. At room temperature, a
typical processing time for the adhesive is about 5 minutes.
To ensure safe installation:
⇒ Install the PLS core (black part) only once into the PLS base (grey part) on the final installation
⇒ Do not bring a magnet near the PLS (this would power the device).
position (parking lot).
⇒ Install the PLS core properly into the PLS base.
⇒ Avoid to uninstall and reinstall the PLS core after the initial installation into the PLS base.
⇒ Do not open the sensor core.
Now you can mount the sensor in the center of the parking space by applying light pressure on the sensor base (see
Fig. 12 Sensor base attachment). Make sure that the sensor is centered in the parking space and that the Bosch logo
on the sensor base points towards the access road (see Figure 13 Sensor base installed). Subsequent twisting of the
sensor base is not possible.
© Bosch Connected Devices and Solutions GmbH 2020. All rights reserved, also regarding and disposal, exploitation, reproduction, editing,
distribution, as well as in the event of application for industrial property rights.
Figure 11 Adhesive amount
Warning
7 | 16