Commissioning And Maintenance; Releasing The Transducer; Instruments Admissions; Dimensional Drawing - Camille Bauer SINEAX I 552 Mode D'emploi

Masquer les pouces Voir aussi pour SINEAX I 552:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10 11 12 13
+
4-20 mA
Fig. 7. Locations of the potentiometers P201 and P200.

7. Commissioning and maintenance

Switch on the power supply and the measuring input. It is
possible during the operation to disconnect the output line and
to connect a check instrument, e.g. for a functional test.
No maintenance is required.

8. Releasing the transducer

Release the transducer from a top-hat rail as shown in
Fig. 8.
Fig. 8

9. Instruments admissions

Germanischer Lloyd
Type approval certificate: 12 258-98 HH
CSA approved for USA and Canada
file-nr. 204767
FCC Compliance and Canadian DOC Statement
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to both
part 15 of the FCC Rules and the radio interference regu-
lations of the Canadian Department of Communications:
These limits are designed to provide reasonable protec-
tion against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
a residential area is like to cause harmful interference
in which case the user will be required to correct the
interference at his own expense.
P201
P200
0,5

10. Dimensional drawing

112.5
114.1
Fig. 9. Housing type P13/70 clipped onto a top-hat rail
(35 ×15 mm or 35×7.5 mm, acc. to EN 50 022).

11. Declaration of conformity

EG - KONFORMITÄTSERKLÄRUNG
DECLARATION OF CONFORMITY
Dokument-Nr./
I552.DOC
Document.No.:
Hersteller/
Camille Bauer AG
Manufacturer:
Switzerland
Anschrift /
Aargauerstrasse 7
Address:
CH-5610 Wohlen
Messumformer für Wechselstrom mit Hilfsenergie-Anschluss
Produktbezeichnung/
Product name:
Transducer for AC current, with power supply connections
Typ / Type:
SINEAX I 552
Das bezeichnete Produkt stimmt mit den Vorschriften folgender Europäischer Richtlinien überein,
nachgewiesen durch die Einhaltung folgender Normen:
The above mentioned product has been manufactured according to the regulations of the following
European directives proven through compliance with the following standards:
Nr. / No.
Richtlinie / Directive
89/336/EWG
Elektromagnetische Verträglichkeit - EMV - Richtlinie
89/336/EEC
Electromagnetic compatibility -EMC directive
E M V /
Fachgrundnorm /
E M C
Generic Standard
Störaussendung /
EN 50 081-2 : 1993
Emission
Störfestigkeit /
EN 50 082-2 : 1994
Immunity
Nr. / No.
Richtlinie / Directive
73/23/EWG
Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungs -
grenzen - Niederspannungsrichtlinie - CE-Kennzeichnung : 95
73/23/EEC
Electrical equipment for use within certain voltage limits - Low Voltage Direc -
tive - Attachment of CE mark : 95
EN/Norm/Standard
IEC/Norm/Standard
EN 61 010-1 : 1993
IEC 1010-1 : 1990 + A1 : 1992
Ort, Datum /
Place, date:
Unterschrift /
Signature:
D i e s e E r k l ä r u n g b e s c h e i n i g t d i e Ü b e r e i n s t i m m u n g m i t d e n
genannten Richtlinien, beinhaltet jedoch keine Zusicherung
von Eigenschaf t en. Die Sicher heit shinweis e der m it gelief ert en
Produktdokumentationen sind zu beachten.
10
11
12 13
1
2
3
4 5
6
7
8
9
70
Messverfahren /
Measurement methods
EN 55011 : 1992
IEC 1000-4-2 : 1991
IEC 1000-4-3 : 1995
IEC 1000-4-4 : 1988
IEC 1000-4-5 : 1995
IEC 1000-4-6 : 1995
IEC 1000-4-11: 1993
Wohlen, den 28. Januar 1998
M.Ulrich
Leiter Entwicklung
This declaration certifies compliance with the above mentioned
directives but does not include a property assurance.
The safety notes given in the product documentations, which are
part of the supply, must be observed.