Device Specification; Process Data - Balluff BTL6-U110-M PF-S4 Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BTL6-U110-M _ _ _ _ -PF-S4
Magnetostrictive Linear Position Sensor – Profile Style
6
IO-Link interface (continued)
6.2

Device specification

Specification
Transfer rate
Minimum cycle time of device
Frame specification:
Amount of preoperate data required
Amount of operate data required
Enhanced parameters
IO-Link protocol version
Amount of process data from the device to the
master
Amount of process data from the master to the
device
Manufacturer ID
Device identification
Tab. 6-1:
Device specification
Transfer times
Process data cycle with 1.0 master
Process data cycle with 1.1 master
Tab. 6-2:
Device transfer times
6.3

Process data

The BTL outputs a signed integer value (32 bits) via the
IO-Link interface. This integer value is a relative
specification of the factory default null point. The specification
resolution is 1 μm/digit.
The measurement resolution of the BTL is 5 μm.
Intermediate values are not displayed in the
output value.
The factory default null value can be shifted within the
measuring range via the parameter Null point offset. The
value 0 specifies the position of the magnet (see parameter
data on page 14).
In the case of an error, if no magnet can be detected, the
maximum value 0x7FFFFFFF or 2147483647 is output as
an error value. Additionally, the data is labeled as invalid.
www.balluff.com
IO-Link Description
COM3
min cycle time
M-sequence capability:
Preoperate M-sequence type
Operate M-sequence type
ISDU supported
Revision ID
ProcessDataIn
ProcessDataIn
Vendor ID
Device ID
Number of PD x master cycle time = 4 x 1 ms = 4 ms
master cycle time = 1 ms
Value
230.4 kBaud
0×0A (1ms)
0×1B
2 bytes
2 bytes
Supported
0×11 (version 1.1)
0×83 (4 bytes)
0×00 (0 bits)
0×378
0x030101
english