BTL6-U110-M _ _ _ _ -PF-S4
Magnetostrictive Linear Position Sensor – Profile Style
6
IO-Link interface (continued)
6.4
Parameter Data
Sub-
Index
index
0x0010
0
Vendor Name
0x0011
0
Vendor Text
0x0012
0
Product Name
0x0013
0
Product ID
0x0014
0
Product Text
0x0015
0
Serial Number
0x0016
0
Hardware Revision
0x0017
0
Firmware Revision
0x000C
0
Device Access Locks
0x000D
3
Profile Characteristic
0x000E
0
PD Input Descriptor
0x0018
0
Application Specific Tag
0x0040
0
Null point offset
0x0041
0
Takeover of null point
offset
Tab. 6-3:
Parameter data of IO-Link interface
Access to subindex 0 address the entire object
of an index. Access of subindices > 0 addres-
ses the individual elements of an index.
Device Access Locks
With this standard parameter, it is possible to activate or
deactivate certain functions of the IO-Link device. With
BTL, there is the option to lock the function of the parame-
ter manager. To do so, bit 1 of the 2-byte value must be
set to 1 (locked). In order to unlock the parameter mana-
ger, bit 1 is set to 0.
Bit
Function
0
Lock parameter access (not supported)
1
Lock parameter management (supported)
2
Lock local parameterization (not supported)
3
Lock local user interface (not supported)
4...15
Reserved
Tab. 6-4:
Lock parameter data
14
english
Parameter
Size
7 bytes
15 bytes
Max. 40 bytes
12 bytes
27 bytes
Max. 18 bytes
2 bytes
9 bytes
2 bytes
6 bytes
3 bytes
32 bytes
4 bytes
Boolean
(1 byte)
Parameter-
Access
management
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read/Write
Yes
Read Only
No
Read Only
No
Read/Write
Yes
Read/Write
No
Write Only
No
Profile Characteristic
This parameter indicates which profile is supported by
the IO-Link device.
BTL supports the smart sensor profile with the following
function classes:
Subindex 1 (Profile Identifier -> DeviceProfileID):
0×0001 (Smart Sensor Profile)
Subindex 2 (Profile Identifier -> FunctionClassID):
0×8000 (Device Identification Objects)
Subindex 3 (Profile Identifier -> FunctionClassID):
0×8002 (ProcessDataVariable)
PD Input Descriptor
This parameter describes the composition of the process
data variables used.
The BTL processes the process data variable as follows:
Subindex 1: 0x032000
0x03 -> Data type = IntegerT
0x20 -> Data size = 32 bits
0x00 -> Offset = 0 bits
Application Specific Tag
The Application Specific Tag makes it possible to assign
the IO-Link device an arbitrary, max. 32-byte string. This
can only be used for application-specific identification and
applied in the parameter manager. The entire object is
accessed via subindex 0.
Default value
"BALLUFF"
"www.balluff.com"
"BTL6-U110-Mxxxx-PF-
S4"
"BTL6PFIOLxxx"
"Balluff Position
Transducer"
"YYMMDDXXXXXXXX"
"XX"
"vX.XX.XXX"
0x00 0x01 0x80 0x00
0x80 0x02
0x03 0x20 0x00
0