Concentrated Solution
Reverse osmosis (Figure 2) is created if a force is applied to this column of water. Thus the direction of water flow through
the membrane can be reversed. This is the basis of the term reverse osmosis. This reversed flow produces "permeate"
water from the salt solution, since the membrane does not permit most salt to pass through it. The typical rejection of a
semipermeable membrane is over 95%. This means that it will reject 95% of the salts and let 5% pass through.
III. Specifications
The W-Series systems achieve highest efficiency with softener pretreatment or low hardness. Highest productivity is
achieved with integrated blending capability for listed part numbers.

System Specifications

Model
Part Number
Blending Capability
Pump / Motor
Dimensions
Weight, Dry (lb)
Weight, Wet (lb)
Install Method

Operating Specifications

Nominal Permeate Flow (gpd) @ 77°F
1
Water Efficiency
Min Inlet Water Temperature (°F)
Max Inlet Water Temperature (°F)
Min Inlet Pressure (psi)
2
Max Inlet Pressure (psi)
2
Nominal Working Pressure (psi)
Max Working Pressure
Feed Water
Feed Water Type
Max Feed Water TDS (ppm)
Max Hardness
Max Free Chlorine
pH Range
pH Range (Optimum)
Max Silica (SiO
)
2
Max Iron (Fe)
Max Hydrogen Sulfide (H
S)
2
Max Manganese (Mn)
Turbidity
Silt Density Index (SDI)
Measured with prefiltered, softened water at 500 mg/L TDS, 40 psi inlet pressure, and 77°F at 60 Hz. Membrane performance may vary +/- 15%.
1
A pressure regulator must be installed to ensure inlet pressure does not exceed 65 psi.
2
W-Series Owner's Manual
Semipermeable Membrane
Dilute Solution
Figure 2
W-500
109820
109825
Yes
No
32
34
Wall Mounted to Studs
500
450
Pressure
Concentrated Solution
W-1000
109830
Yes
24VDC, 1.7GPM
30" W x 8" D x 14" H
38
41
1000
70%
35˚F
90˚F
25
65
110
140
Softened Municipal
2,000
<5 grains
<0.1 mg/L
4 - 11
5 - 8
10 mg/L
<0.05mg/L
<0.05 mg/L
<0.05 mg/L
<1.0 NTU
<5.0
4
Dilute Solution
109835
No
900