5.1 Measured values that are available at the bus interface, depending on the application

Table 1:
Sym-
Meaning
bols
U
Input voltage
U12
Phase-to-phase voltage
L1 – L2
U23
Phase-to-phase voltage
L2 – L3
U31
Phase-to-phase voltage
L3 – L1
U1N Phase-to-neutral voltage
L1 – N
U2N Phase-to-neutral voltage
L2 – N
U3N Phase-to-neutral voltage
L3 – N
UM
Average value of the
voltages
I
Input current
I1
AC current L1
I2
AC current L2
I3
AC current L3
IM
Average value of the
currents
IMS
Average value of the
currents and sign of the
active power
IB
RMS value of the current
with wire setting range
(bimetal measuring function)
IB1
RMS value of the current
with wire setting range
(bimetal measuring function),
phase 1
IB2
RMS value of the current
with wire setting range
(bimetal measuring function),
phase 2
IB3
RMS value of the current
with wire setting range
(bimetal measuring function),
phase 3
BS
Slave pointer function for the
measurement of the RMS
value IB
BS1
Slave pointer function for the
measurement of the RMS
value IB, phase 1
BS2
Slave pointer function for the
measurement of the RMS
value IB, phase 2
BS3
Slave pointer function for the
measurement of the RMS
value IB, phase 3
Application
(see table 2)
A11
A24 /
...
A34
A44
A16
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
Sym-
Meaning
bols
F
Frequency of the input
variable
P
Active power of the system
P1
Active power phase 1
(phase-to-neutral L1 – N)
P2
Active power phase 2
(phase-to-neutral L2 – N)
P3
Active power phase 3
(phase-to-neutral L3 – N)
PF
Active power factor
cosϕ = P/S
PF1
Active power factor
phase 1, P1/S1
PF2
Active power factor
phase 2, P2/S2
PF3
Active power factor
phase 3, P3/S3
Q
Reactive power of the
system
Q1
Reactive power, phase 1
(phase-to-neutral L1 – N)
Q2
Reactive power, phase 2
(phase-to-neutral L2 – N)
Q3
Reactive power, phase 3
(phase-to-neutral L3 – N)
S
Apparent power of the
system
S1
Apparent power, phase 1
(phase-to-neutral L1 – N)
S2
Apparent power, phase 2
(phase-to-neutral L2 – N)
S3
Apparent power, phase 3
(phase-to-neutral L3 – N)
LF
Power factor of the system
LF1
Power factor, phase 1
LF2
Power factor, phase 2
LF3
Power factor, phase 3
QF
Reactive power factor
sinϕ = Q/S
QF1
Reactive power factor,
phase 1, Q1/S1
QF2
Reactive power factor,
phase 2, Q2/S2
QF3
Reactive power factor,
phase 3, Q3/S3
EA
Energy meter 1
EB
Energy meter 2
EC
Energy meter 3
ED
Energy meter 4
Where c.t's and/or v.t's are used for measurement, the values
are referred to the primaries of the transformers.